Radiator tails weeping | General DIY Plumbing Forum | Plumbers Forums

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Discuss Radiator tails weeping in the General DIY Plumbing Forum area at Plumbers Forums

Messages
40
Hi all,

I fitted my first rad the other day and unfortunately both tails are weeping. Whilst holding the tail in my left hand I wrapped ptfe between 15 and 20 turns clockwise. I screwed them in with my radiator spanner as far as they would go, not quite up to the last thread though.

Im going to drain the system (its only a couple of rads) and try again. I guess the options are to try and screw them in a little further? Or Shall I start again and try more turns or slightly less turns and make sure the tail is fully screwed in up to the last thread. Its a cast iron radiator.

Any tips appreciated.

IMG_20241019_170719.jpg
 
More ptfe around 24 wraps
 
While draining down the rad, why don't you cut the fixing bracket back and hide it inside the cast iron rad.
It's 3 column so you can hide it behind the first or second column.

Also, the connections where the tails connect to the rad are brutal. You might want to clean them out with screwing a 1/2" thread into them a few times to clean them out a little. Lubricate the female thread and then screw in your tail.
The cast iron tapping doesn't allow the tape into thread all that good due to its roughness.

When you remove the tail, I doubt there will be any tape in the threads
 
Hi all

Finally got round to taking this rad down and this is what the tails look like when removed. As you can see a section of PTFE has been forced to the front of the thread.

Oz, what should I use to lubricate the female thread?

Or should I use liquid thread seal? I got some Flomasta pipe seal but i'm a bit dubious about using this..

IMG_20241029_164152.jpg
 
Scratch a hacksaw blade across the threads so you cause little grooves.
It's called 'roughing up the thread'.
Apply PTFE, lubricate the male and female threads and screw the thread in.
As said previously,the cast iron threads are brutal / sharp and tear the tape to pieces.
Roughing up the male thread assists with keeping the tape on the thread.
 

Similar plumbing topics

  • Question
Finally got it to seal - ptfe paste to fill...
Replies
12
Views
5K
  • Question
Was it Hoval or Ideal valves? Used to have...
Replies
5
Views
769
  • Question
Already have the trvs
Replies
11
Views
2K
  • Question
Need a gas safe engineer sorry to say
Replies
13
Views
2K
  • Question
If there's a bit of flex in the pipes, you can...
Replies
10
Views
4K
Back
Top