Search results | Page 2

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. moonlight

    My Husband used to do all the plumbing? What is the worst DIY plmbing you have seen?

    The previous plumber just plunged it and left. There is no way water runs uphill and even less with tea bags and coffee grains. :):p
  2. moonlight

    My Husband used to do all the plumbing? What is the worst DIY plmbing you have seen?

    Had a customer the other day with a blocked sink. she said it never used to get blocked before, her husband used to do all the DIY jobs. Look at this mess.
  3. 2018-02-13 14.53.54.jpg

    2018-02-13 14.53.54.jpg

  4. moonlight

    Geberit 236 replacement

    Just out of interest. Has anyone fitted a different model from the Geberit 236 flush valve into the same cistern fitting. I know the twico model changed and the new one would fit into the same cistern fitting. Cheers in advance.
  5. moonlight

    Is there a seperate certificate, for a gas fire.

    I have never needed to do one. My customer had her boiler and fire serviced. I failed the gas fire as it was spilling. I said it could be cobwebs. She has now had the chimney cleaned. I have been back refitted the fire and tested. Passed both tests. Do I re-issue a cp12? or is there another form...
  6. moonlight

    Safety Check on a Coalbrookdale fire?

    Has anyone recently done a LGSC at a house with a Coalbrookdale fire in it? What did you test? I know its not a gas appliance but it still burns solid fuel and produces CO2. Any insight would be good. Thanks.
  7. moonlight

    Worcester greenstar 24i

    Usual visit to my boilers not working. I am not sure where to start. Anyway I have power to the boiler from the fused switch. Blown fuse. Replaced. Turn power back on pop goes the fuse. Can't test past the fuse as it blows instantly. Is this the transformer or a board issue? Thanks in advance...
  8. moonlight

    Readings for the gas valve on a baxi bermunda

    Hi does anyone know what the readings dc for the gas valve are, I have an electronic ignition. The pilot lights but continually clicks and doesn't come on for main flame. Not very helpful at baxi, the person I spoke to seemed to think there was a button near the circuit board. Wrong boiler. He...
  9. moonlight

    Worcester Greenstar 28i leak

    I went to complete a landlords gas safety check Friday and found a couple of leaks on this boiler. One was the automatic air vent the other? See the picture. Is this the heat exchanger that has failed or just the seal? I haven't taken it apart as yet I have to report back to the landlord and...
  10. moonlight

    Customer buying own invented cylinder.

    I have a customer who's neighbour works at a plumbers merchants. He has told my customer it is better to have an external expansion vessel as lots of his customers at the merchants have said they have had problems with internal ones. Have any of you had problems with internal? One more thing...
  11. moonlight

    Would you fit a water softener? and can you see its merit?

    I have been asked by an old customer of mine if they should have a water softener fitted in their new build house. I am not a fan of them but would like an unbiased view, so I could give them the information required. They now live 200 miles away so I wont be fitting anything but still would...
  12. moonlight

    How do you gas rate an appliance with a new smart meter?

    I haven't had to do one as yet. Two LGSC recently and they had new meters, just would like to know before I have too. Thanks.
  13. moonlight

    New DIY'er in Birmingham

    Hello Farenheit :)
  14. moonlight

    Do you have a phone full of other peoples bad work?

    I was looking through my phone today, trying to clear up my storage and came across a few ringers. What pictures do you have on your phone that you don't mind sharing?
  15. moonlight

    Emergency Plumber. Out of hours.

    I dont think the person who did this should call themselves a Plumber:eek: No wonder the toilet kept running :eek:. Nice new valve fitted. Trading standards now involved.
  16. moonlight

    Customer couldn't find a plumber to stop the leak through the ceiling so did this.

    I went to look at a job the other week. Customer said the had a leak in the airing cupboard. There was a nut he wanted me to tighten. Flow and return on coil leaking but not from the compression fitting. The cylinder was damaged. I said he needed new cylinder. He also said he had a leak in the...
  17. moonlight

    How many cisterns have plastic liners?

    I came across this the other day, I have never seen a cistern with a plastic liner. How many other manufactures do this?
  18. moonlight

    Have you tried one of these? The new Quick fit Flush valve.

    anyone tried one of these valves yet? I can't see the point of fitting a different drop valve in place of the one you have? Its saying you don't have to remove the cistern to fit? Interested in your views
  19. moonlight

    Honeywell ST699 Replacement

    Hi All, Just wondering if anyone knew what would be the best replacement programmer for the Honeywell ST699? Other than like for like. My customer has a y plan system. Useful if the back plate matched. I don't want a pack just the programmer. Thanks
  20. moonlight

    DIY Hi

    Hello, from Wiltshire
Back
Top