  1. Bibbs118

    Weird wiring/pump over run

    Hi, I've got a rewire job next week. The current setup, old cast iron boiler with pump over run, (currently wired so pump over run isn't working). There is a (new) 2port and pump to the cyl with cyl stat with bypass. There is a bronze pump for DHW There is a (big) pump for the CH. (And...
  2. Bibbs118

    Worcester 30si round heat ex given me

    Jip. Hi, just thought I'd post to see if am missing out . About boiler going to over heat, flashing red reset blue light one flashes off . Been a number of times now, I've seen the fault happen in hw and ch, I tested the flow temp and it didn't seem high at all, 55 degrees. Customer reported...
  3. Bibbs118

    Measuring rads W x H or H x W

    Ok, so if your in the Gas Safe forum you can view my worst week ever. One of the jobs that went wrong in that week was a basic rad single panel for double swap, should have been nice and easy, plenty of movement on the 10mm pipe. Only it went wrong because I turned up with a 600w by 400h rad...
  4. Bibbs118

    Vokera intermittent fault.

    Hi guy's, looking for a bit of tech help on this job. I've not been yet, I'm going on Wednesday, another Engineer has been but says he can't find anything wrong with it. Apparently it locks out after being on for 15 mins. I had one like this a few years back and I tried loads of things but...
  5. Bibbs118

    Remeha avanta condensate hole

    Hi Guys. I wonder if you help try an settle an argument that has been rumbling on between me and my BG mate. When the case rusts around the trap on the Remeha and there is a visible hole ID or AR. I have rang baxi and gas safe and they say the same thing, but I'll not say just yet so it...
  6. Bibbs118

    Gas Tag is coming..........

    Hi guy's, What does everyone think about this Gas Tag thing that is coming in next year, there was a short piece about it in this month's Gas Engineer magazine saying it's going to be put in 7 million homes. They claim it will cut out the cowboys but I'm struggling to see how as it just...
  7. Bibbs118

    Cast Iron style rads on 10mm

    Hi, A customer wants cast iron style rads throughout, 9 or 10 in total but currently has 10mm pipe . Is there any problems installing this type of rad on mircobore? I'm worried about the water content being much higher and it not circulating? Anyone else installed these on mircobore? Cheers