Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Leaking isolation valve after depressurisation of boiler in the Boilers area at Plumbers Forums

Messages
4
Hi

Need some advice please, my boiler dropped pressure so I attached the filling loop to the Tribune cylinder and added some water to rectify the pressure issue. Pressure is all good on boiler and CH is working, I now have a constant drip from the valve. Are these easy to replace? Any assistance would be appreciated as I have had to stop the water into the property.

Picture attached

2785F8C0-8ACF-4EA0-AB92-E1AD176EF3ED.jpeg
 
Not bad have to drain down but just two compression nuts to undo and tighten
 
There are valves out there not designed for heating temperatures. Plus you need a check valve so the heating water can not get back into the mains water
https://www.NoLinkingToThis/p/r24-filling-loop/83905
 
That’s actually the one I was looking at more by luck than judgement though. Anything I need to be mindful of when removing /replacing my existing one?
 
Yes turn off mains water and drain the heating down a little. If you’re confident you could relieve the pressure by bleeding a radiator then snatch it. Just ensure that the check valve is in place and the arrow pointing the right way
 

Similar plumbing topics

T
I know you must be frustrated, but as gmartine...
Replies
4
Views
465
Fits back on flue on top of boiler
Replies
3
Views
612
It seems to be a case of having to watch and...
Replies
8
Views
668
That means you have a leak as the system...
Replies
9
Views
814
Ok great...really hoping it wasn't a leak.
Replies
6
Views
635
Back
Top