Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Hot water temperature advice. in the Bathroom Advice area at Plumbers Forums

Messages
51
Hi,

I've got a combi valiant ecotec plus 837 with a control vrc 430 weather compensator controller fitted.

The picture attached is the mains display of the vrc 430 with both heating and water set to auto.

1) The only purpose I have used auto is for the heating to kick in when it's in for the heating timer. Is there any other purpose for it to be on auto?

2) what is the purpose for the hot water to be set to auto if this is a combi boiler. Isn't the purpose of the combi boiler to have hot water on demand? There is currently no timer settings settled for the domestic hot water.

3) what is the best temperature to have the hot water set on? As from the pic, it's set at 50 C but I've read online and a few sites recommended at 60 C.

Thanks in advance.

1552679835448407550328667494561.jpg
 
Not come across a VRC430 in a while and certainly haven't programmed one for ages! If it's anything like the Worcester ones, the timer settings for the HW I would imagine are for the 'Comfort' mode. So you can have comfort turned on during set periods so you get HW quicker, but can have it off during the night to save gas and prevent the boiler coming on.

HW temp can be whatever you want, doesn't matter as it's a combi. I usually recommend 55oc. If you had stored HW like an Unvented cylinder then different matter.
 
Google it and download instructions if you don’t have them. It can be used to control domestic hot water (dhw) from an additional source. I’m not sure it relates to comfort mode.

Stored dhw - 60 degrees
Combi - user preference, but I usually set between 60 and 65.
 
Hi CBW1982. Sorry to jump in on thread. I work with oil boilers, as you may or may not know oil combi’s have a thermal store or slave tank to aid in HW production. Are there any gas combis that are similar in design or store HW? I’m not trained on gas so wouldn’t know
 
Hi CBW1982. Sorry to jump in on thread. I work with oil boilers, as you may or may not know oil combi’s have a thermal store or slave tank to aid in HW production. Are there any gas combis that are similar in design or store HW? I’m not trained on gas so wouldn’t know

Hi SJB, I'm not to sure tbh, I only ever fit combi's and just those. Perhaps someone else may know?
 
Thanks Evil. Oil combis use a store, they use a timer to bring store up to temp to speed up HW production. If the store is cold then that volume of tank needs to be brought up to temp before you get HW at taps. Like I said I’m not trained on gas, what I know about gas is what little we learnt at college and what I’ve studied since. I know the principles behind gas boilers, pipe sizing and everything else you’d expect an engineer to understand but have know experience with gas like I say. My work only consisted of PJ and VS/VP burners
 
will be some kind of hot water pre heat

60 dc
 
So Shaun one last question if you don’t mind. These gas storage combi’s. Are all the stores like oil combi’s as in the store is pre heated to supply instant heat to PHX when a tap is opened or are some an actual storage for DHW taps? Sorry if this is a stupid question, I’m just trying to further my understanding of gas boilers.
 
So Shaun one last question if you don’t mind. These gas storage combi’s. Are all the stores like oil combi’s as in the store is pre heated to supply instant heat to PHX when a tap is opened or are some an actual storage for DHW taps? Sorry if this is a stupid question, I’m just trying to further my understanding of gas boilers.

Correct but they use the same water eg you take your supply from the tanks until it runs out normally vaillants are around the 15l mark they also have a strat pump moves the hot water to the bottom etc
 
Got you. As far as I know oil combi’s don’t have a stratification pump. Wether it’s a diverter valve or two pump system the water is pumped through the bottom of oil combi’s storage before coming out the top and going through the PHX to heat DHW.
 

Similar plumbing topics

The timeclock is hopefully fairly self...
Replies
3
Views
575
  • Question
40*C in the danger zone for legionella growth...