What is this lead plumbed in? box (fireplace) | Plumbing Jobs | The Job-board | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss What is this lead plumbed in? box (fireplace) in the Plumbing Jobs | The Job-board area at Plumbers Forums

Messages
1
It's a very heavy looking lead plumbed in(?) box behind the fireplace. There used to be a 70/80's gas fire in front of it.

I don't want to start removing it if it's plumbed into the mains. However running a tap doesn't make a noise of water flowing through it.

Any ideas gratefully received.

IMG_20190425_115903461.jpg
 
It might well be dead and dis connected BUT may still contain water...be carefull they
can get a bit frisky if you where to put a stove or open fire in without removing..cash it in at the local scrap man ...I would
centralheatking
 
It looks like a solid fuel back boiler. Although I have never seen that pattern.
What is your current heat and HW set up. A pic of the airing cupboard would help to confirm that it is dead

When I said "dead", I meant not connected. But, as per Rob, being dead does not guarantee empty. If I remove an old boiler of that type, I establish that it is not connected so cannot refill, and then drill a small hole - in this case in the lead tails. Have buckets, and an asssistant, ready to catch the water. You can drill at an angle to ensure the water jets in the right direction.

BTW - I cannot recall seeeing a BB plumbed in Lead, round our way it is copper or iron, and the connections on the side. I assume the boiler itself is cast iron?
 
If the pic was added later, why is the link to the pic at the bottom of quoted reply? o_O:D
it was national hug a plumber day yesterday, guess what I got a belated hug from Trevor a long term customer today, and we had a pint in the Scotch Piper at Lydiate ...have a nice weekend centrakheatking
anyway whatever the op seems happy and might get some lolly
for that lead boy..
 
It might well be dead and dis connected BUT may still contain water...be carefull they
can get a bit frisky if you where to put a stove or open fire in without removing..cash it in at the local scrap man ...I would
centralheatking

Yes I've seen a few that have exploded sending the contents of the fire into the room. Some people drill holes in them but I think removal is the best option
 

Similar plumbing topics

  • Question
Ok thank you Chuck, yes it does a bit 😆 That's...
Replies
6
Views
443
Make sure there is a means of isolating the...
Replies
2
Views
349
Lloyd999
L
  • Question
Many thanks for the advice.
Replies
3
Views
798
    • Like
Alpha 2/3 manual. Shows variant with air...
Replies
8
Views
1K
Thanks. It's a 2017 Grant oil condensing...
Replies
2
Views
2K
Back
Top