Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Full bore isolating valves- which way round to fit? in the Plumbing Jobs | The Job-board area at Plumbers Forums

Messages
26
Hello chaps,

Just fitting some full bore isolating valves. No arrows on the casing for water flow direction.

The screwed joint is one side of the ball valve.

Is there any preference with which way to fit them ? Does it matter?

Cheers
11495.jpg
 
theres an arrow on them but normally the small / split outlet
 
If no arrow then shouldn't matter Andy but personally I would install with flow running from left to right in your photo.

I seem to remember when they first came out the joint between the two halves of the valve was alway to be on the upstream side.
 
Thanks for the info chaps,

I wonder what the reasoning is??

I fitted them the opposite way around- my idea was there was one less joint to leak on the pressure side.

I might swap them later.

Cheers
 
Mechanically they are symmetrical so it shouldn’t really matter.

I think most manufacturers add a flow direction arrow because it does matter with some other valve types and people expect to see them.
 
If no arrow, id always fit them with the solid inside face on the feed side, the solid machined side when you look inside the valve if that makes sense
Why, a fellow plumber disconnected the feed side of one of these in some flats, temporarily, as it wasn't letting by he for whatever reason didn't bother to cap it and went home, during the night the ball part blew out of the open end of the valve, the valve had no arrows, but if the valve had been oriented the other way it wouldn't have been able to happen
 

Similar plumbing topics

  • Question
Thanks Shaun, Much appreciated. It's nice to...
Replies
2
Views
662
  • Question
Any valve is in essence a service valve. I...
Replies
13
Views
6K
  • Question
Normally the split on the outlet where the hex...
Replies
7
Views
1K
  • Question
Nice one. Thanks. Got them off and was able to...
Replies
2
Views
864
  • Question
Why is it outside? It will freeze and the...
Replies
1
Views
643
Back
Top