Aqualisa From Pumped To Unpumped Processor | Plumbing Jobs | The Job-board | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Aqualisa From Pumped To Unpumped Processor in the Plumbing Jobs | The Job-board area at Plumbers Forums

DjClubber

Gas Engineer
Messages
50
Can you just convert the Processor from the Fully Pumped over to the Un Pumped Processor if the installation is just at the moment Pumped but being converted to a Combi? Ideally want to keep the Ceiling Fed Kit Below and just be able to change the Processor? Will it Wire in the same and be able to use the Start / Stop below? Please can you let me know ASAP??? TY...

The pic shows the manual with both, the pumped is installed at mo but ideally want to change to unpumped for Combi. . .

aqualisa.jpg
 
I think so have to change the whole unit like you say eg from pumped to mains / high pressure but you can keep everything else I think
 
Thanks, appreciated. Will order unpumped version. . . Thanks for the quick replies. Once again Appreciated. . .

The one in the pic ?
 
How do you do it? Push fit sockets onto the stems, take it to copper and then compress a full bore valve onto the copper or do you attach the valves direct to the plastic stems on the valve.

Over the years, using both the grey & black processors, I've done both. What dictated which was used, was simply ease of pipework access.

The last one was approx 18 mths ago and that was direct onto the plastic stems on the supplies and via a pulled bend on the output.
 
Very bad idea

Well they say you learn something new every day!

25 years plumbing and installing countless versions of these showers I did not know you could not do just switch them over. :oops:
(Although I have never needed to).

That brings another question, why the hell is it there then?
 
Well they say you learn something new every day!

25 years plumbing and installing countless versions of these showers I did not know you could not do just switch them over. :oops:
(Although I have never needed to).

That brings another question, why the hell is it there then?

MRB. Every day is a school day :D

If you look closely you'll see that the label is split into the two types of processor. The RH one is the pumped version & the LH one the HP version.

Truth is it's a little confusing. It's all about Aqualisa saving money to use a common label.
 
Well they say you learn something new every day!

25 years plumbing and installing countless versions of these showers I did not know you could not do just switch them over. :oops:
(Although I have never needed to).

That brings another question, why the hell is it there then?
If you look at the cover of the processors you will see that the pumped and standard versions have different pressure ratings. The pumped are only rated for low pressure where the standard versions are rated for higher pressure. I found out the hard way :oops:.
As Dave said, it's a money saver for aqualisa so they only produce one pcb for both the standard and pumped versions. And probably a money maker as your forced to change the processor if you change your system.
 

Similar plumbing topics

    • Like
Alpha 2/3 manual. Shows variant with air...
Replies
8
Views
1K
Who said plastic 28/22mm copper tube and mlcp...
Replies
3
Views
795
More than fine then in 11/5 tube should be...
Replies
3
Views
633
    • Like
  • Article
The UK Government has today been told to do...
Replies
0
Views
766
Back
Top