Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Electric boiler recommendation in the Boilers area at Plumbers Forums

M

MOSSEP

Hi

Ive got a client who wants central heating fitted in a coach house that has no gas supply, can anyone recommend a decent electric boiler? Its not a small place so I can't see much online that looks suitable, total heating load is around 22kw - 4 bed place with poor insulation, and then it has 3 bathrooms so a big unvented cylinder will go in so need to add 3 - 6 kw for that too.

Thanks for any input.

Martin
 
Have a look at ehc (electric heating company)
 
Hmm. Their ongoing costs are going to be horrific and theyll be paying to oversize their htg requirements.
IMHO it would be good sense to seriously look at installing insulation where they can to minimise both their ownership costs as well as seriously reducing the size of boiler reqd. They'd win all round ;)
 
You'll need to consider the spare capacity of the existing electrical supply.
It might rule out an Electric boiler altogether.
Depending on the property location upgrading it could run into tens of thousands.
 
The slim jim is shocking dont look at that one. Fitted one and first of all the pcb had a loose connection on it and the overheat stat seems to be made of chocolate.

Haven’t had any trouble with the 2 I’ve fitted
 
EHC is what I use as but really only suitable for a small property as Dave has said the running costs are very expensive and I made sure the places were very well insulated , you may find they never modulate down , upgrade the insulation and personally I would look at lpg . Kop
 
running costs will be huge regardless of what fuel is used is used if the buildings insulation isn't sorted. I would go with a heat pump which if done proper will beat any LPG or oil by miles
 
As above insulation, draught proofing doors and windows anywhere heat can escape is vitally important, your load will be huge when added together with all other electrical appliances, electric panel type rads on a economy 10 tariff and a separate pressurised direct cylinder maybe a option, personally in the heart of winter I don't think the boiler would achieve the temperature required in the property of that size . Kop

Screenshot_20190722-095508.png


Screenshot_20190722-095528.png
 

Similar plumbing topics

Thanks to @ShaunCorbs and @cjg for the helpful...
Replies
7
Views
804
P
Baxi boilers are light and quiet but I doubt...
Replies
15
Views
2K
Are you controlling the stove flow temperature...
Replies
6
Views
1K
Don't know if there are older / newer versions...
Replies
2
Views
2K
C
Seems reasonable but I'd still rather have...
Replies
1
Views
852
Back
Top