Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Drop fed rads - draining from rad tail. in the Plumbing Jobs | The Job-board area at Plumbers Forums

Messages
120
Im planning to drain down my CH system to do some work on it and also replace a couple of rads.

All of the downstairs rads are on individual drop feeds with most of the pipe work on 10mm microbore ( a few have had 15mm adapters and 15mm pipe added)
There are no drain cocks on any of the rads downstairs.

The rads which use 10mm pipe have got 15mm valves fitted and use 10 to 15mm valve reducers which were a pain to fit and get a good leak free seal

In the past ive been able to drain individual legs using a short length of copper pipe with a nut an olive on one end and a hose on the other as a makeshift drain off point connected to the rad valve (ive only done this on the pipes that have been adapted to 15mm.

I dont really want to use the above method on the 10mm drops as I dont want to have to displace the rad valves and adaptors.

some of newer rads that i fitted a while ago have valve extensions with integral drain taps like this.....
upload_2019-7-24_21-42-27.png


just wondering, would it be possible to drain the entire leg from this point meaning i could leave the valve and reducer set undisturbed?
 
Isolate both sides of the Rad, take the Rad off but be careful as its full of water... I put a tub under and cap of each side of the Rad then take outside to empty.
Then you can drain from the Rad tails... I have tails off old rads with drain offs tightened in on a nut and cone to drain the legs
 
I assume you know but just incase you don't all drops have to be drained seperatly the first one you drain will drain upstairs and that one drop (open the bleeds aswell) and then all other drops will need draining if your working on them
 
I assume you know but just incase you don't all drops have to be drained seperatly

Yes i already knew that but thanks for the heads up

Isolate both sides of the Rad, take the Rad off but be careful as its full of water... I put a tub under and cap of each side of the Rad then take outside to empty.
Then you can drain from the Rad tails... I have tails off old rads with drain offs tightened in on a nut and cone to drain the legs

I was hoping to avoid having to do this
.. Reason being is that the 10mm pipe is set in the concrete floor so there's no play at all in the pipes. Only way to maneuver the rads out is to very gently 'flex' the pipes outwards to create clearance and remove the rad.

Every time I do this im worried about fracturing one of the pipes so was looking for an alternative approach
 

Similar plumbing topics

  • Question
Red circles show my new AAVs and the manual...
Replies
17
Views
2K
Hi All This is following on from thread I...
Replies
0
Views
594
  • Question
Correct. Bleed from bottom up to allow air...
Replies
3
Views
1K
  • Question
Your over thinking this do as I said the...
Replies
9
Views
1K
A simple thing i'd probably check is the...
Replies
9
Views
1K
Back
Top