Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss First time I’ve seen this. in the Plumbing Jobs | The Job-board area at Plumbers Forums

Timmy D

Esteemed
Gas Engineer
Subscribed
Messages
937
Both flue and air held together with cooking grease.

Spent the first hour cleaning!
 

Attachments

  • 49EB49B1-09FB-45D2-9EF1-B8BE013A04CC.jpeg
    49EB49B1-09FB-45D2-9EF1-B8BE013A04CC.jpeg
    1.8 MB · Views: 68
  • 3511CE4F-607C-4063-B5EB-5768570A1B34.jpeg
    3511CE4F-607C-4063-B5EB-5768570A1B34.jpeg
    2 MB · Views: 70
We’re they Smokers aswell ?
 
Looks a bit damaged to me o_O

Both air and flue cracked in the centre of all 4 sides. Residents complaining of headaches...co escaping.

The closest flue brackets (unistrut/threaded rod), only had 1 screw holding it up. The screw and plug where half out, clips/pipes all wonky.

Can see any other reason for the spigot breaks apart from the weight of the unsupported flue/air.

Crappy ex council install.
 
Evening mate. Have you sent either me, @ShaunCorbs or @Riley your gas safe details over?


Hey buddy. Sent to Lou recently, still awaiting confirmation.

I’ll send you a copy now.

Cheers
[automerge]1567202555[/automerge]
As CBW1982 flue connector spigots look broken! If so I.D. it & replace them.

Another firm ID it, I went to fix.

Both broke, one of the pics is me lifting the spigot while the bolts are still done up on the boiler.

Cracked all the way through.

Renewed spigot, some flue/air, clips, full service, grease clean, additional access panel for inspection in ceiling.
 
Last edited:

Similar plumbing topics

Bit late to the show but I would have beeen...
Replies
2
Views
771
Hi everyone I currently work in oil and gas...
Replies
0
Views
1K
As a precaution report this to the building...
Replies
1
Views
1K
Yep, that's what I meant (as per attached...
Replies
7
Views
1K
N
  • Question
Brilliant, thanks for that info, will be very...
Replies
16
Views
1K
Novice needs help
N
Back
Top