A

Aire

Hi guys, got a Worcester greenstar 30cdi to service, I checked it last year and fan pressure was with acceptable limits but boilers 5 years old thos year so will need burner cleaning out. Am I right in thinking you need a special brush as well as a burner gasket or is it just the gasket I need? Thanks
 
Yes best to around £30 for the seal and gasket

Plus another £10-£20 for the top gasket

Also electrodes
 

Attachments

  • E57EF034-691A-4B1C-A6B0-3FFF3D58F4C1.jpeg
    E57EF034-691A-4B1C-A6B0-3FFF3D58F4C1.jpeg
    1.7 MB · Views: 28
Thanks chaps, never serviced a Worcester before so thought I'd double check. Is the top seal and front seal seperate items then, don't they sell a kit that comes with both and the brush kit?
 
Thanks chaps, never serviced a Worcester before so thought I'd double check. Is the top seal and front seal seperate items then, don't they sell a kit that comes with both and the brush kit?

Brush and front seal eg the door will come as one

Top seal is separate

Also electrodes are Separate
 
Ok thanks, how likely is it the electrodes will need changing?

Highly normally last around 5 years max (pic was 6 and giving ea lockout once and a while)

You can also do the bearning plate if it hasn’t been done
 

Attachments

  • 4F2BBC05-E9A1-4AAC-8A80-D0F95BA1618E.jpeg
    4F2BBC05-E9A1-4AAC-8A80-D0F95BA1618E.jpeg
    1.4 MB · Views: 26
TBH around £150 coves is ish
 
Yeah looking around £80 for parts and should allow 2 hours labour as I've not done one before so don't need to be rushing.
 
He will soon moan if you don't strip & then it goes **** up in the middle of the winter.
Do it once & do it properly.
He can then start saving for the next time it reqs a major strip/service out if boiler lasts that long.
Best to change the bearing plate also because it usually takes the fan out if one of the flaps separates & goes through.
Cheers,
Andy
 

Similar plumbing topics

What's wrong with the people who fitted it...
Replies
4
Views
542
Yes will also more than likely need...
Replies
1
Views
577
Hi all. I hope you are well. Need some advice...
Replies
0
Views
554
Thank you for reply. I have isolated the noise...
Replies
2
Views
414
I've tidied up this thread and banned a user...
Replies
2
Views
1K
Back
Top