Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Condensate trap on one year old boiler in the Boilers area at Plumbers Forums

Matt0029

Gas Engineer
Messages
1,177
Any idea why the condensate trap on a one year old ideal boiler would have so much sediment in it as seen in the picture? On other one year old boilers of the same model on this estate the condensate trap is clear. In the one in the picture there is also sediment in the black pipe that connects to the top of the trap.
 

Attachments

  • IMG_20190913_125454.jpg
    IMG_20190913_125454.jpg
    2.9 MB · Views: 32
Did you ask of any frequent venting of rads? Any leaks on system? As you haven’t mentioned which system/boiler lid on tank ok? As Scott suggests dust entered system somehow?
 
It's on a sealed system so no tanks house around 10years old. I swapped the boiler about a year ago, the system water seemed clean when drained down. We did a flush too.
 
ive seen worse than like almost like tango i belive its something to do with the stainless hex and the manufacturing process
 
I’ve come across two like this an it related to constant pressure loss on sealed system. Haven’t heard back since replacing heat exchanger, all the basics was ruled out in previous visits exp vessel, prv etc. The first one I had boiler had been off for couple days, removed sump cover an pressurised the system to 2 bar you could literally see it pooling water at the bottom of the sump. May not be your issue but the 2 I have come across with dark sediment in the trap seemed to be internal leak on heat exchanger

*edit*
Just thought I’d mention I had no idea if they was a year old
 

Similar plumbing topics

In a one-pipe heating system with a condensing...
Replies
7
Views
446
Hi all, Pipe moved...Temporarily fed back...
Replies
5
Views
684
It’s ok aslong as the internal trap is the...
Replies
2
Views
1K
Theres nothing so fanciful on these traps...
Replies
5
Views
3K
Jeff the lonesome
J
When replacing an old Certikin 180 oil pool...
Replies
2
Views
584
Back
Top