Does anyone know how this happens | Plumbing Jobs | The Job-board | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Does anyone know how this happens in the Plumbing Jobs | The Job-board area at Plumbers Forums

Sue66

Gas Engineer
Messages
41
Pinhole leak in old thick copper cold pipe for no apparent reason. See middle of picture
 

Attachments

  • 20190913_151724.jpg
    20190913_151724.jpg
    1.2 MB · Views: 95
Pinhole leak in old thick copper cold pipe for no apparent reason. See middle of picture
Lots of possible causes (Google it). It often said that copper pipe lasts 20-50 years.

If you are lucky, it'll be one defect in an otherwise good system. More realistically, it'll be the first of several in that run of pipe. If you are unlucky, pinholes will start appearing everywhere over the next few years and you'll need to re-pipe the whole house.

Personally, I'd replace the run at this point and have a critical look at the appearance of any other easily visible pipes. If the surface looks 'dimpled' that section is probably on its last legs.

If you do need to re-pipe, my advice would be to use branded high-quality tube such as Yorkshire, not some no-name stuff from China via ebay. (I suspect that plenty of people these days would repipe in plastic but I'm a dinasaur and I don't like the stuff.)
 
Could it be uncleared flux?
There was nothing on the outside. I just don't get it.
[automerge]1568408379[/automerge]
Struggling with this quote malarkey but Yes I see what you mean. So basically even really thick copper can just suddenly pin hole everywhere even though its super thick and this is just the first to appear.
 
Had one a week ish ago was just full of flux
 

Attachments

  • 1358C582-8721-45B4-871D-780AD503A8DC.jpeg
    1358C582-8721-45B4-871D-780AD503A8DC.jpeg
    1.2 MB · Views: 82
  • 41CB4A62-41CD-4EA1-B21D-84AEA4CD52E7.jpeg
    41CB4A62-41CD-4EA1-B21D-84AEA4CD52E7.jpeg
    273.7 KB · Views: 76
  • 65D730CB-DDCD-4255-B318-FC9133BA877C.jpeg
    65D730CB-DDCD-4255-B318-FC9133BA877C.jpeg
    2.2 MB · Views: 77
  • 0DB14D11-F267-420A-9AE0-DB217D658F7B.jpeg
    0DB14D11-F267-420A-9AE0-DB217D658F7B.jpeg
    1.6 MB · Views: 75
I don;t know w'y it happened.

but about 10 years ago, I had done a conventional to combi swap. Tidying up and getting paid. waked in the kitchen and water was squirting up through the kitchen floor. It was a quite magnificent fountain display, what you would see in a municipal pond / fountain. Had to replace about 9M of hot water pipe.
 
I don;t know w'y it happened.

but about 10 years ago, I had done a conventional to combi swap. Tidying up and getting paid. waked in the kitchen and water was squirting up through the kitchen floor. It was a quite magnificent fountain display, what you would see in a municipal pond / fountain. Had to replace about 9M of hot water pipe.
Love the image reminds me of Vegas. The bellagio or whatever it's called. Sound bloody awful from our perspective though
 
Sue,

It is more likely to be a result of the water quality that the pipe work quality. Bimetallic corrosion, high chlorine levels or high PH are all key contributory factors. Look for slight dimpling elsewhere on the system for an indication if this is the start of a longer term issue
 
Are you on a private water supply? Ours is very acidic & 15mm copper won't last 5 years (which I found 37 years ago after completely re-plumbing our "new" house in copper😡 I had to redo it all in plastic, since when all OK)
I sent pipe samples off to IMI etc etc & was told it was probably flux deposits which I found strange since it often occurred in vertical runs. When the water supply failed one day I went to the spring to investigate & found the brass tank connector on the collection tank had completely dezincified & could be crumbled with my fingers - THEN the penny dropped!
 
Maybe plastic from now on then. First time I'm actually thinking this!
Don't be put off Copper by that. It is more than likely an impurity in the Copper. It might not happen again. Don't worry about it.
If it is corrosion caused by external influence, there is normally some kind of indication of that in my experience.
Plastic.........Ew no! Be a proper Plumber. He Ducks in readiness for the onslaught!
 
Thanks for all your helpful And interesting responses to my question everyone. The pipe was left with the customer so I don't have it now for further analysis. Hopefully it was a one off problem but judging by some responses this may not be the case!
 
I was told by an older and wiser plumber that back in the 60's / 70's cheap copper pipe was being imported from "Africa", possibly Nigeria.
He reckoned it pinholed after a few years, particularly where bends had been pulled.
It was Rhodesian copper tube, very thin walled and fragile. It does pinhole and when you work on it often developes leaks eleswhere
came accross it in Bath years ago. centralheatking
 

Similar plumbing topics

It's the bottom one, floorstanding. It's a...
Replies
2
Views
436
  • Question
With patience, I’ve not come across a socket...
Replies
4
Views
882
  • Question
Are you on mains water? I had the same problem...
Replies
4
Views
2K
Still same have you fitted a new board
Replies
6
Views
813
  • Question
Depending on what size/type your existing rad...
Replies
5
Views
962
Back
Top