Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Durgo position in run? in the Plumbing Jobs | The Job-board area at Plumbers Forums

Messages
6
Hi,

We’re converting an old store/workshop joined to our house and installing a small shower room with the wastes connecting to the old clay pipe in the floor where the original toilet once was.

We needed to bring the floor up 100mm for insulation and had a plumber set the new waste pipes for the basin and shower within this and connect to the clay pipe before we put the floor boards down.

Building control say we need to install a durgo valve and the plumber has not currently allowed for one on the run.

I’m wondering if we need one at the end of the run (sink), where everything joins the stack, or both...

My main issue is that the 110mm stack is positioned quite far forward away from the wall in the floor (220mm) so I’m already trying to use a space saving pan connector which will not allow a boss. If I can ‘get away’ with just the AAV at the sink end then that’s great, but I don’t want any problems further down the line.
 
I think you will need one bigger than a sink one

Could you have one in the corner by the toilet eg stub stack

1569224316537.jpeg
 
Thanks for the reply.

Ideally I would, just not sure how to get the pipe work in place for it and still fit the toilet without setting it even further forward.

The rooms already tiny so was going to get a short projecting toilet. Was hoping to avoid having to build out the wall but maybe that’s my only option?

I’ve attached a photo of the toilet waste as it’s been left. Was even contemplating getting an offset coupler in the floor to push it back to the wall further as it’s currently 220mm from the wall and 200mm seems to be the limit for most toilets to sit back flush.

Any thoughts?
 

Attachments

  • A7D591DD-E39D-4AD1-ABF6-160D0C22ED7A.jpeg
    A7D591DD-E39D-4AD1-ABF6-160D0C22ED7A.jpeg
    1.3 MB · Views: 20
As it looks like a timber floor why not adjust the waste so you have a vent on the left and your toilet on the right ?
 
As it looks like a timber floor why not adjust the waste so you have a vent on the left and your toilet on the right ?


Not sure I have the height to be able to do it.

The timber floor sits on 100mm insulation laid on top of the old concrete floor. The existing clay pipe sat above the concrete floor so the plumber used a shallow Macalpine coupler with boss to bring it just below current floor level and be able to connect the shower/basin waste.

I can’t see that we can branch off and keep the height low enough?
 
Need to start digging down into the concrete to add a tee
 
Can you install a vent on the outside?

In theory I could go through the side wall to the left but I would still have the issue of being able to branch off what’s there?
[automerge]1569279018[/automerge]
Spoke to a plumber friend tonight and he said I could possibly tee off in 40mm to the AAV. Do you think this is acceptable?

It would mean changing the pan connector to one that isn’t space saving as I can’t see that one exists but I’d rather pack the toilet off the wall 50-100mm than dig out the concrete...
 
Last edited:
I wouldn’t say so best people to ask is building control as they will be signing it off
 
Get your plumber to find the nearest vent and see if it in allowable distance for the new fixtures.
If the original pan didn't have a vent then whu should the new pan require a vent.
You may be adding a couple of new fixtures, but that shouldn't hinder the ventilation of the drain.
I'm all for adding vents into drains, and if in doubt add one, but not when one is not necessary.
AAV's for me are an absolute last resort, I would rather vent to atmosphere
 

Similar plumbing topics

  • Question
If you go and put your hose in the top like...
Replies
1
Views
285
  • Question
Soil comes into the building at 45. I was...
Replies
2
Views
796
F
Ok great thanks for your advice and swiftness...
Replies
5
Views
1K
FeelingCold
F
  • Question
Not if you’re joining up with the old one. I...
Replies
1
Views
2K
Deleted member 120897
D
  • Question
Hi Welcome! Could anyone offer their advice?
Replies
1
Views
502
Back
Top