Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss No hot water - help needed in the Bathroom Advice area at Plumbers Forums

Messages
8
Hi everybody

I live on my own and my parents are away so in desperate need of some help!!

I have a Vaillant Eco Tec Pro boiler. On return from holiday a few days ago, my heating wouldn’t come on and the hot water was luke warm. I noticed the water pressure had dropped to nil and the thermostat batteries had gone flat. After sorting out the water pressure and changing the batteries in the thermostat the boiler seemed back to normal. My heating now works perfectly. However I noticed I now have 0 hot water. When I turn the hot water rap on, nothing comes out. Also, when the heating is turned on the water pressure sky rockets off the scales but drops soon as I turn the heating off. When pressing the “i” on the boiler I notice it says error code S31 which means the thermostat is blocking heat. I have already changed the batteries and i’m not sure what other options to try. I have reset the boiler many times, nothing is changing. I urgently need hot water for showers/washes and am struggling - can anybody help?!
 
All valves open below the boiler as it sounds like you might of shut something off to top up the pressure by accidentally
 
All valves open below the boiler as it sounds like you might of shut something off to top up the pressure by accidentally
Hi, perhaps I have. I have take
All valves open below the boiler as it sounds like you might of shut something off to top up the pressure by accidentally
Perhaps I have yes?! I’ve attached a picture as no idea how to know if ones open
 

Attachments

  • image.jpg
    image.jpg
    805.6 KB · Views: 25
This valve looks shut

Should be a 1/4 turn
 

Attachments

  • BCDE684D-1A09-4C82-9B39-A4579957269C.jpeg
    BCDE684D-1A09-4C82-9B39-A4579957269C.jpeg
    105.4 KB · Views: 25
This valve looks shut

Should be a 1/4 turn
Thank you so much I now have hot water!!! Unfortunately now my heating isn’t working. The boiler / heating turns on for a bit then switches off. The thermostat under the boiler now shows 0 lights (it has no batteries for me to change) and the code S30 (thermostat blocking heat) is showing again - attached pics for reference
 

Attachments

  • C5722422-11F2-4005-B488-ABFC06EEB524.jpeg
    C5722422-11F2-4005-B488-ABFC06EEB524.jpeg
    1.2 MB · Views: 17
  • 92CCFA31-1627-4865-9365-F70027BFC9F8.jpeg
    92CCFA31-1627-4865-9365-F70027BFC9F8.jpeg
    1 MB · Views: 13
Do you have heating if you press button 2 eg override
 
You may have to re bind the room thermostat to the receiver

Best option is to google the instructions

As s30 is no demand
 

Similar plumbing topics

C
  • Question
Is there a ball valve on the flexihoses? Might...
Replies
1
Views
858
  • Question
You Can Use Boiler, Heat Pump.
Replies
3
Views
566
  • Question
IME Mira showers of that age are usually very...
Replies
1
Views
583
76 Views and not one single "expert" has...
Replies
5
Views
576
  • Question
Thanks. I'll try to find a hard copy as I...
Replies
3
Views
902
Back
Top