Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Advice on me mam's bathroom in the Plumbing Jobs | The Job-board area at Plumbers Forums

WaterTight

Esteemed
Plumber
Subscribed
Messages
5,433
I don't get involved in bathrooms really so pretty clueless. Only doing it because it's my mum's and she doesn't mind how long it takes so I can take my time and work it out as I go along.

We're changing the bath to a roll top and fitting wall panels. Today I remove the old tiles and some plasterboard to suss out the state of the walls.

Two walls are solid, one plasterboard/studwork.

Can I fit the wall panels straight to the studwork on the plasterboard wall?

For the two solid walls they are bit soft and water invaded round the rim of the old bath in a few small patches. The rest seem sound. Would it be wise to cut off the gunk and get it skimmed by a plasterer on the gammy sections before installing the panels on those two walls? And can they go straight onto the walls once skimmed?

Finally I've got a boiler warning pipe, condensate pipe, a hot and cold feed and a basin waste which I'd ideally like to move back and re-route behind the wall panels, re-appearing in the corner so mostly hidden behind the new bath. Is that too much pipework to put through the stud work with an angle drill do you think? If so it can be boxed just in front of the new wall panels. It was boxed before apart from the two boiler pipes which were clipped in front of the boxing.

Hope that all makes sense? Any advice appreciated. Thanks

73238905_425519264815398_3738309993653338112_n.jpg
75258506_468964170392028_9214617454691483648_n.jpg

73475206_780312442408372_2431956546243002368_n.jpg
74938765_921727948210381_7108381487191293952_n.jpg
 
No, need to re plasterboard the walls

Better off hacking the old stuff off that’s loose and depending on depth getting a plaster to dot and dab some plasterboard on don’t skim it leave it blue faced (moister resistant plasterboard)

I would say the basin waste would be too much for the wall but the condy and services would be fine
 
Small boxing in just shy of the ped ??
 
Yeah sounds like a plan. Do you reckon some off cuts from the wall panels could be used over the boxing to blend in with the walls?

Yes you could even use the same trims or mitre for a real blend
 
Don't do anything until you get a dehumidifier in there to dry the room out you really don't want to trap that moisture in , hack the old plaster off back to brick or block dust down and sbr to seal, green plaster board is moisture resistant dot and dab the solid walls and screw new plaster board to the timber uprights insulate in-between , strip that sh-te out a couple of units in there with hide alot of the new pipework box in the bits that show. Kop
 
I don't get involved in bathrooms really so pretty clueless. Only doing it because it's my mum's and she doesn't mind how long it takes so I can take my time and work it out as I go along.

We're changing the bath to a roll top and fitting wall panels. Today I remove the old tiles and some plasterboard to suss out the state of the walls.

Two walls are solid, one plasterboard/studwork.

Can I fit the wall panels straight to the studwork on the plasterboard wall?

For the two solid walls they are bit soft and water invaded round the rim of the old bath in a few small patches. The rest seem sound. Would it be wise to cut off the gunk and get it skimmed by a plasterer on the gammy sections before installing the panels on those two walls? And can they go straight onto the walls once skimmed?

Finally I've got a boiler warning pipe, condensate pipe, a hot and cold feed and a basin waste which I'd ideally like to move back and re-route behind the wall panels, re-appearing in the corner so mostly hidden behind the new bath. Is that too much pipework to put through the stud work with an angle drill do you think? If so it can be boxed just in front of the new wall panels. It was boxed before apart from the two boiler pipes which were clipped in front of the boxing.

Hope that all makes sense? Any advice appreciated. Thanks

View attachment 41076View attachment 41077
View attachment 41078View attachment 41082
Whatever you do do not use plasterboard or any derivative, there are really great totally
water resistant back boards used them loads of times. The normal grout whatever they claim will
let moisture in then the plasterboard expands and blows all the tiles off. if you like I will ask marc..our tiler what this stuff is called. he always uses Stainless Steel strips and expensive grout...never a come back ..centralheatking
 
Whatever you do do not use plasterboard or any derivative, there are really great totally
water resistant back boards used them loads of times. The normal grout whatever they claim will
let moisture in then the plasterboard expands and blows all the tiles off. if you like I will ask marc..our tiler what this stuff is called. he always uses Stainless Steel strips and expensive grout...never a come back ..centralheatking

hardie backer or wedi/marox board

one problem i find they say its not effected by water and water can travel through without any effect so still requires waterproofing so better just to tank it

but as hes using panels where theres only one point of entry around the bath no need just need a decent bath strip/seal
 
If you're going to dot and dab, seal any cracks first. Should make for a significant reduction in heat loss otherwise you may find you're you're thermally separated from outside by a thickness of plasterboard and whatever is on top of it only.
 
Thanks everyone. Very useful info.

Like the idea about a unit to hide some of the pipework Kop. Will get a dehumidifer in there too.

Some other things:

Sorry, what is tanking? I did google but still not sure. Is it a term for having dot and dabbed water resistant plasterboard onto the solid wall as is being suggested by several of you? Or something else?

The space between the current wall on the left and the studs on the wall on the right is I think 1780mm. The roll top bath going in is 1700mm wide (already purchased and sitting in next room.) So not a lot to play with. ..

Do you think once plasterboard and then wall panels are fixed to stud wall on the right and the solid wall on the left is dot and dabbed I will still get the bath in? On looking it up it seems that the blue plasterboard is 12.5mm thick, with ahesive behind it...running out of room big style... Any ideas?

In case it helps re: the waterproofing situation it's a roll top bath and I was hoping there would need be no cuts or joins along the rim of the bath. Was thinking of doing ceiling to floor all round, then put bath in. But would be nice to have a spare 25mm wriggle room to actually get the thing in!

Thanks
 
I would do the walls floor to ceiling should be fine your using panelling so no need to tank - tanking is a paint on waterproof membrane I would prime the plasterboard though before fixing the panels . Kop
 
.So the walls will brought out by what 25mm once done?
[automerge]1572166280[/automerge]
Also in case I decide I don't want to risk doing a naff job on the wall panels (being my first time and my mum's place 'n' all) what trade is best off contacting for fitting them? A tiler? Plasterer? Decorator?
 
Last edited:
Thanks

The warning/overflow pipe from boiler (not sure what proper name is) which I'd like to run behind the new bath... Is this going to be ok or are there maximum distances this could violate? Not a big extra distance.
 
But cal go in the wall with the others with a slight fall to outside
 
Further bit of advice please.

I fear - in hindsight - it was unwise to remove the tiles before having a scheduled plan for sorting the walls out. I am getting quotes for people to do the walls (plasterboarding/wall panels etc) but in the meantime I've stripped half the plasterboard wall back to studs and my mum still needs to use the bathroom (her only one.)

I've hung plastic sheeting across the exposed part, gaffa taped around the corners and told her to leave windows open after washing but am worried that if it's several weeks or more before the walls are done enough moisture could get to the back face of the regular plasterboard which comprises the wall in the lounge opposite.

If the exposed part is well covered with plastic sheeting and I regulary remove it and dry the inside with blue roll before replacing am I going to be ok for a few weeks if need be or is this a disaster waiting to happen?

Not used to plasterboard or it's tolerances to such things. The solid walls I'm less concerned about as can hack off the damp bits and leave a calor gas heater and some dehumidifiers in there for a few days before they get done

Hopefully I'm over-worrying and it'll be ok doing this for a few weeks...?
 
I will help you out here bud don't leave poor old mum like that below is our sponsor the wetroom store (we get a discount on there), go on the site and get some therma panel delivered 1200 x 900mm x12mm sheets simply screw to the battens every 300 mm as below you may need to add extra timber ? the board is a cement faced foam tile backer board and can be cut really easily with a saw its100% waterproof and you can either tile on to it after tanking or stick panels to its so easy your mum could do it 🤣silicone the panel to the bath and you can then work on it as and when you have time but it's now waterproof and a bit more tidy and no more water damage. Regards kop
 

Attachments

  • Screenshot_20191102-052406.png
    Screenshot_20191102-052406.png
    132.8 KB · Views: 23
  • Screenshot_20191102-052425.png
    Screenshot_20191102-052425.png
    164.7 KB · Views: 28
  • IMG_20190730_151253.jpg
    IMG_20190730_151253.jpg
    85.4 KB · Views: 32
  • IMG_20190731_163352.jpg
    IMG_20190731_163352.jpg
    106 KB · Views: 25
  • IMG_20190806_163149.jpg
    IMG_20190806_163149.jpg
    65.3 KB · Views: 27
  • IMG_20190809_184929.jpg
    IMG_20190809_184929.jpg
    70.6 KB · Views: 21

Similar plumbing topics

  • Question
Much easier than that is to replace your bath...
Replies
3
Views
2K
  • Question
There is hopefully a lintel above that new...
Replies
5
Views
3K
Thanks for everyones advice. With some...
Replies
3
Views
4K
Replies
9
Views
936
Back
Top