Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Help - changing wireless thermostat in the Central Heating Forum area at Plumbers Forums

Messages
34
I recently posted on here as I was having problems with my wireless thermostat and receiver, turns out the receiver has developed a fault.

I have decided to change the old set up for a new receiver and wireless thermostat.

However the wiring set up is different on the new unit ( a Honeywell/Center unit EHE0200361 ) the old unit is a Salus ST620RF
Boiler is Worcester Greenstar CDI

Could anyone help me with the wiring please.

I have attached photos of the old and new receivers.

many thanks
 

Attachments

  • IMG_20191104_110452.jpg
    IMG_20191104_110452.jpg
    85.1 KB · Views: 32
  • IMG_20191104_113515.jpg
    IMG_20191104_113515.jpg
    59.7 KB · Views: 26
  • IMG_20191104_113549.jpg
    IMG_20191104_113549.jpg
    66.6 KB · Views: 27
Blue to n
Brown to l
Earths together in a chock block
Black to a (this should be into the com port on the old)
White to b

That’s a bit of a guess as can’t make out the writing
 
Thanks Shaun,

Do I need to link both the ' L ' terminals together on the new Center box ?

Which writing can you not make out - I will take another photo to clarify if this would help

many thanks
 
Thanks Shaun,

Do I need to link both the ' L ' terminals together on the new Center box ?

Which writing can you not make out - I will take another photo to clarify if this would help

many thanks

No just put the wires on the left L

And the back wire there should be writing below the terminal block
 
Thanks for that.

The writing on the Salus connector block reading left to right is

COM NO Earth Live Neutral

regards

My info then is correct
 
Thank you. Much appreciated :)
you may find youll struggle to get the two cables into the honeywell as you need two neutrals and two lives which look 1.5 maybe 2.5mm. one drawback with this receiver is very small wiring terminals. black and grey no problem as one cable per terminal. the two browns can go one each into the live terminals, the right hand live is just a common live youd use to link to terminal A if you were not doing no volt switching. just be careful with the two blues into one terminal dont have too much bare cable showing on the neutral and live terminals closest together very easy to short out
 
Last edited:
Great thanks for the update
 

Similar plumbing topics

Yes the Siemens would bind to the boss one, I...
Replies
7
Views
951
Deleted member 120897
D
That is true - however with Vaillant...
Replies
4
Views
848
M
Replies
5
Views
2K
Sounds more like the heating zone valve isn’t...
Replies
5
Views
1K
Deleted member 120897
D
From the crappy instructions I’ve found, it...
Replies
5
Views
1K
Back
Top