Belfast sink worktop cutting. | General DIY Plumbing Forum | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Belfast sink worktop cutting. in the General DIY Plumbing Forum area at Plumbers Forums

Messages
578
Have to fit a Belfast sink to an oak worktop. Have a jig on the way. Reading all the blurb about using the jig all the makes seem the same. Namely they state the worktop should overhang the sink by 10mm, both sides and rear. Also that the worktop should be level with a datum line drawn through the front of the sink by half its thickness. I have no idea why these figures have been selected can anyone enlighten me?
 
The internal width of the sink - 20mm eg 10mm either side

as for front the sink wants to be proud by half the thickness of the casting eg the thickness of the side divide 2

but most of the time there on the same front as the worktop
 
Agree with what you are saying my question why is it decided on 10mm and half the thickness of the sink? My sink is only 20mm thick anyway so basically worktop will cover half of thickness sides and back. Why can I not overlap it more say 15mm sides and back. And does it really matter if it overhangs the front by more than half the thickness? I have seen photos where they overhang by a lot more than that. And on another point not sure how this drip groove works. In my situation if I adhered to the 10mm sides/back and set the drip grove back another 5mm, as suggested, and routed it to 5mm width the edge of it will be directly inline with the sink edge?
 
I guess it gives maximum opening for pots and pans you can cut it to what ever size you want
 
I guess it gives maximum opening for pots and pans you can cut it to what ever size you want
Suppose one can just wondered who invented the 10mm:)
[automerge]1594285096[/automerge]
Attached is a drawing of my setup. Due to the sink only being 20mm thick setting back 10mm will not work evidenced by A
I will have to adopt one of the methods B or C .
C to my mind is best as none of the drip grove is in contact with the sink.
Most jig makers suggest a drip groove 5 -6mm wide but Trend suggest 2.5mm is fine.
sink x.jpg
 
Last edited:
C personally for me as it’s got a drip edge also maybe another grove further in for sealant ?
 
C definitely looks the best option and have seen photos with the worktop overhanging and they look okay to me.
Has been suggested I use Plumbers Gold for the sealant have you ever used it? I was just going to use a good silicon
sealant till pointed in the direction of this stuff.
 
Tbh it doesn’t really matter aslong as it’s decent
 

Similar plumbing topics

  • Locked
Great that how I will do it then. Thanks
Replies
11
Views
3K
  • Question
I would tend to agree with snowhead the...
Replies
9
Views
4K
Basically sounds like nothing was set in stone...
Replies
21
Views
6K
P
  • Locked
  • Question
With hose in place down grey pipe,air can...
Replies
15
Views
22K
R
  • Locked
Hey all, apologies for the long post: I've...
Replies
0
Views
4K
richardc1983
R
Back
Top