Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Can a conventional system boiler be a closed system? in the Boilers area at Plumbers Forums

Messages
18
As per the title?

I've only ever seen domestic system/conventional system boilers with an F&E tank and combi boilers which are closed systems.

Is there any reason a system boiler cant have an expansion vessel fitted and be made a closed system?

Or

Is there any reason you couldn't install a combi with an open vent/F&E?
 
The following applies to the UK and its regulations:
1. You can have sealed systems with combi (always sealed), system boilers or open vent boilers provided the manufacturer allows this - these days they nearly all do.
2. You can't really run a combi boiler off an F&E tank, as the pressure is unlikely to be sufficient to pressurise the system. Also, you'd lose the benefit of mains pressure hot and cold.
 
You would need to consult the manufacturers installation manual for that particular boiler.
I have seen all manner of configurations over the years but the manufacturer is the place to start if you're thinking of altering or installing something.
 
The following applies to the UK and its regulations:
1. You can have sealed systems with combi (always sealed), system boilers or open vent boilers provided the manufacturer allows this - these days they nearly all do.
2. You can't really run a combi boiler off an F&E tank, as the pressure is unlikely to be sufficient to pressurise the system. Also, you'd lose the benefit of mains pressure hot and cold.

Hadn't thought of the system pressure, that makes sense with a combi.
[automerge]1597826034[/automerge]
You would need to consult the manufacturers installation manual for that particular boiler.
I have seen all manner of configurations over the years but the manufacturer is the place to start if you're thinking of altering or installing something.

It was more out of curiosity as a newbie, @stedysons comment on pressure makes sense with the combi.
 
As per the others a consultation with the manufacturer would be a worth while chat. This is an extract from the Intergas (Netherlands based) eco rf30 manual which gives different configurations:
 

Attachments

  • D53A57C6-08D9-4FF0-946B-079B845C1A20.jpeg
    D53A57C6-08D9-4FF0-946B-079B845C1A20.jpeg
    26.4 KB · Views: 25
The following applies to the UK and its regulations:
1. You can have sealed systems with combi (always sealed), system boilers or open vent boilers provided the manufacturer allows this - these days they nearly all do.
2. You can't really run a combi boiler off an F&E tank, as the pressure is unlikely to be sufficient to pressurise the system. Also, you'd lose the benefit of mains pressure hot and cold.

Why does a combi boiler require pressure to operate yet a system boiler doesn't?

Is this a protection mechanism or is it designed to increase the boiling point of the heating medium?
 
Why does a combi boiler require pressure to operate yet a system boiler doesn't?

System boilers do require pressure to operate, it’s heat only/open vent boilers that do not. A sealed system only gets rid of the feed and expansion cistern in the loft. It can be fed onto a gravity hot water system or an unvented cylinder.
 

Similar plumbing topics

Would an open hot water tap / open radiator...
Replies
1
Views
719
Stick with heat only. You most probably still...
Replies
3
Views
949
update on this, attached the Kinetico HE water...
Replies
4
Views
2K
System boilers have a pressurised heating...
Replies
1
Views
260
Back
Top