I wonder if anyone could help.
Problem: We have no hot water and the heating comes on when we switch the hot water on from the boiler programmer to heat the hot water up.
Our boiler is a Potterton Suprima or (Supr1ma).
What we’ve done so far: My neighbour switched the three port valve so we could have hot water heated up from the immersion tank instead of the boiler .
My brother changed the 3 port valve to the same ‘Center’ 3 port valve.(we had water coming out of the over flow tank in the loft, I think it was the radiator tank,-we think it is a faulty over flow ball valve). We tried another 3 port valve incase the new one was faulty but Changing the 3 port valve - Didn’t work.
My brother changed the boiler programmer (Potterton EP2002 to an Ep2) because the old one had a broken leaver and thought it might be a signal problem. - Didn’t work.
Someone said it could be a wiring problem.
We do have a problem with our shower. We have the shower plug switch constantly off and only switch it on when we want to use it because the shower will sometimes randomly come on and to stop it we have to switch the plug on and off to reset the shower. The shower is a Aqualisa Quartz. Could this cause a wiring problem?
Last year we had the fan replaced in the boiler as it stopped working which caused the hot water from heating up and the heating to come on.
Does anyone have a idea as to what the problem could be?
We only moved into this house 2 years ago.
thanks in advance for helping.
Problem: We have no hot water and the heating comes on when we switch the hot water on from the boiler programmer to heat the hot water up.
Our boiler is a Potterton Suprima or (Supr1ma).
What we’ve done so far: My neighbour switched the three port valve so we could have hot water heated up from the immersion tank instead of the boiler .
My brother changed the 3 port valve to the same ‘Center’ 3 port valve.(we had water coming out of the over flow tank in the loft, I think it was the radiator tank,-we think it is a faulty over flow ball valve). We tried another 3 port valve incase the new one was faulty but Changing the 3 port valve - Didn’t work.
My brother changed the boiler programmer (Potterton EP2002 to an Ep2) because the old one had a broken leaver and thought it might be a signal problem. - Didn’t work.
Someone said it could be a wiring problem.
We do have a problem with our shower. We have the shower plug switch constantly off and only switch it on when we want to use it because the shower will sometimes randomly come on and to stop it we have to switch the plug on and off to reset the shower. The shower is a Aqualisa Quartz. Could this cause a wiring problem?
Last year we had the fan replaced in the boiler as it stopped working which caused the hot water from heating up and the heating to come on.
Does anyone have a idea as to what the problem could be?
We only moved into this house 2 years ago.
thanks in advance for helping.