Hi
I need to move my existing external toilet and bath outlets due to having a rear extension built and they foul the roofline.
After advice / opinions on my preferred option which I have included as a sketch.
My main concern is:
1, If I'll need air admittance valves and where they need to be positioned - if I do need them.
2, And whether it would ok / advisable to connect the bath outlet to the proposed toilet outlet....
Just to confirm the existing soil stack is vented correctly above roof level.

Any help / advice / criticism gratefully received.
Cheers Tony
 

Attachments

  • IMG_20210129_100623.jpg
    IMG_20210129_100623.jpg
    249.8 KB · Views: 43
That looks fine, won’t need aav.

I would not connect the bath waste into the toilet outlet unless you can use a short boss pipe with the boss on the top of the ‘horizontal’ 4” ie don’t connect into the side of this pipe.
I suspect this may be too high for the bath waste , in which case run it separately and boss into stack lower down.
 
No need for air admittance valves if stack is correctly vented.
Maybe look at using a access bend where it turns into stack give some rodding access.
I would personally connect the bath waste into the soil stack unless you could get bath connection into top of toilet float which would make bath waste unusually high.
 
Thanks for the replies. Glad you both agree no aav required.
Good tip about providing access bend - thank you.
I'm really struggling to get the bath waste directly into the stack - but agree not a good idea to connect into the horizontal 110mm soil pipe after the toilet.
But I have thought about the below:

I've attached another quick sketch showing where it could go - apologies for the back of *** packet look....
Appreciate not really designed for this but your thoughts appreciated on it as long as it's a good secure fit.
 

Attachments

  • IMG_20210130_124315.jpg
    IMG_20210130_124315.jpg
    274.3 KB · Views: 34
Can you take it through ensuite and outside wall then into stack?
If it needs a vertical drop outside you should consider going up a pipe size and/or including a vent pipe (bit old school)
 
Can you take it through ensuite and outside wall then into stack?
If it needs a vertical drop outside you should consider going up a pipe size and/or including a vent pipe (bit old school)
Can't really do that as just not enough room in the WC unit due to the required 110mm junctions, the toilet outlet levels, and the proximity of the outside stack.
Could this work instead:
 
What about original plan with 135° branch for bath and single waste adapter, angled up as much as is practical.
Think that's my best stab without more major work but still not loving it
 
Yeah agree - not ideal but options limited. Only saving grace is pipework is easily accessible so if any problems fairly straightforward to resolve - hopefully!
Why do you prefer the 135 branch with single adapter in the middle of the bathroom run as opposed to the same adaptor at the end of the ensuite run?
Added to sketch if I've got your idea right.... There is enough room as sketch not to scale
 

Attachments

  • 16120193644324442224014583356522.jpg
    16120193644324442224014583356522.jpg
    260 KB · Views: 32
Less joints in the pan connector option so that has merit.
TBH I recon if it were my job and I had to guarantee the work, then I'd find a way to get it outside.
 

Similar plumbing topics

Thanks, I think its a case of stick with the...
Replies
4
Views
976
10 o’clock / 45 degrees would be better than...
Replies
3
Views
683
Thank you so much - really appreciate the...
Replies
6
Views
2K
If poss i would run to outside to stack.
Replies
1
Views
4K
Thanks alot
Replies
3
Views
3K
Back
Top