Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Toilet Flush Button Stuck in the Boilers area at Plumbers Forums

Messages
25
Hi,
For a while now one of my flush buttons on the toilet has started sticking down and so it just continues flushing. I can get it to pop back up by wiggling it around a bit but this is starting to get quite annoying.
Is there any part of the system I could easily replace myself that would fix this?

IMG_2232 (2).JPG
 
Best to replace the flush as I’ve never seen that type/make before

I normally fit fluidmaster
 
Yes only difference is some are 2” others are 1.5” but the fluidmaster normally comes with an adapter for both
 
I have never seen that sort of arrangement before. That is a flapper valve. If you disconnect the small tube from the valve in the middle will the toilet still fill? Just check the small tube doesn't have any holes in it. It looks like when the fill valve fills the cistern the tube may help to close the flush and lift the buttons back up.
 
This looks like yours.
Thank you, yes that definitely looks like mine, although I can't find anyone actually selling them or one like it?.
Should I disconnect the one end of that tube and just try flushing again to test it?
 
You could disconnect the tube, if the cistern fills ok you could just replace the flush valve. But I think I would replace both as you could well be in the same boat in the future. If you do, make sure you buy a fill valve with a brass tail.
 
It’s a trap primer found mostly on the American side let’s water through after a flush
 
You shouldn’t need one so just any push button siphon should do etc
 
You would need to replace both fill and flush valves
 
Yep that will be fine
 
Hi all,
I've bought the new part and started dismantling the toilet. I've removed both the plastic nuts holding the cistern in place. But how do I undo the inlet valve? I've undone the plastic nut but the cistern will still not come loose. I've tried undoing the top metal nut but when I turn anti-clockwise it turns the whole metal assembly and lower metal nut too. Should I be holding the lower nut with grippers before undoing the upper nut?
Attached is a photo of the assembly.
 

Attachments

  • IMG_2248.JPG
    IMG_2248.JPG
    237.6 KB · Views: 35
Need to hold the plastic steam then undo the brass nut
 
Thank you, I watched some videos too and realised I was turning it the wrong way as well. Why is everything reverse threaded in plumbing? Or is it just upside down?
There is a small rubber washer on the top of the inlet valve, not sure if I get a new one in the fluidmaster packet but I assume I need to make sure that it's put back in when I re-assemble (pic attached)?

Shall I remove all the old silicon on the bottom of the cistern where the holes are? I've seen that it shouldn't be necessary for silicon if you make a good seal?
 

Attachments

  • IMG_2249.JPG
    IMG_2249.JPG
    489.9 KB · Views: 31
Your looking at it backwards

this needs replacing 15MM HEP20 WAVIN FLAT TAP CONNECTOR WASHERS-RUBBER (BAG OF 20) HX58/15 | eBay - https://www.ebay.co.uk/itm/15MM-HEP20-WAVIN-FLAT-TAP-CONNECTOR-WASHERS-RUBBER-BAG-OF-20-HX58-15/291994119470?hash=item43fc34ad2e:g:67cAAOSwtgFbkjzT

Or a pack of 1/2 fibre washers from screwfix

Fibre & Rubber Washers 210 Pcs - https://www.NoLinkingToThis/p/fibre-rubber-washers-210-pcs/70837


yes clean all the old silicon off you don’t require it
Will these do the job too? - homebase is closer for me: Oracstar 1/2 inch Fibre Washer For Flexible Tap Connector - https://www.homebase.co.uk/oracstar-1-2-inch-fibre-washer-for-flexible-tap-connector/12821640.html
 

Similar plumbing topics

Thanks Shaun Much appreciated
Replies
2
Views
234
I recently moved into a new flat and both...
Replies
0
Views
1K
C
Hello My toilet flush is busted. The tank...
Replies
0
Views
616
Chris P
C
R
There are a few things that could be causing...
Replies
4
Views
1K
In the old days, toilets used quite a lot of...
Replies
0
Views
665
Back
Top