Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Water level in toilet cistern rising despite being set in the Boilers area at Plumbers Forums

Messages
2
Hi.
We have a B&Q toilet system (see attached picture) and have an issue where tge water level rises despite adjusting the screw rod.

Example.....
I set it at bedtime last night and the level filled to the line, then this morning it was flushed and when filling again it goes too high and stops at the over flow, causing a trickle of overflow.

I replaced the valve washer as it had perished snd there is no leaking.

Any idea what could be causing this?
I am going away tomorrow and worried that it may start trickling while away.

Thanks.
 

Attachments

  • Screenshot_20210320-064948_eBay.jpg
    Screenshot_20210320-064948_eBay.jpg
    87.4 KB · Views: 42
  • Screenshot_20210320-064948_eBay.jpg
    Screenshot_20210320-064948_eBay.jpg
    87.4 KB · Views: 35
Simple answer stop messing about trying to repair something that's done years of hard work.
Replace it with something decent fluidmaster would be my choice less than £15 even for brass shanked version fit and forget.
 
Hi.
We have a B&Q toilet system (see attached picture) and have an issue where tge water level rises despite adjusting the screw rod.

Example.***.
I set it at bedtime last night and the level filled to the line, then this morning it was flushed and when filling again it goes too high and stops at the over flow, causing a trickle of overflow.

I replaced the valve washer as it had perished snd there is no leaking.

Any idea what could be causing this?
I am going away tomorrow and worried that it may start trickling while away.

Thanks.
Are you setting the level after a flush? As sometimes setting levels on an equilibrium valve with the cistern already partially filled will not give an accurate setting.

I always turn off my stopcock when I go away.
 
1. Which washer did you replace, the inlet valve one or the flush valve one.
2. If the flush valve one, replace the inlet valve washer.
3. Might be a better long term plan to replace as above.
4. If you have an isolation valve on the inlet pipe side, shut it off while you are away.
 
Ha. That's fine happy to change.
Problem is would it be an easy job for someone who does not do any plumbing?
As long as you get the version with the brass shank (i.e the thread that it connects to) and read the instruction leaflet it's at the easy end of the DIY spectrum. If the incoming 'tap connector' has a fibre washer, take care not to damage it and/or have a spare one to hand just in case.

There are a gazillion how-to videos on youtube, this one is from the manufacturer:

 

Similar plumbing topics

  • Question
Thanks for Info
Replies
10
Views
1K
Alright then. Thank you Ben-gee for your...
Replies
2
Views
1K
Unfortuately this is the reality of designer...
Replies
12
Views
6K
Good need mate. Thanks for the feedback.
Replies
12
Views
3K
The float regulates how much water flushes out...
Replies
1
Views
857
A
Back
Top