Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Water mains trench - bend radius in the General DIY Plumbing Forum area at Plumbers Forums

Messages
34
I'm looking to replace my water supply. I will be digging the trench on my side myself. I have all the safe dig plans etc and found the guide on the southern water website:

Screenshot 2021-11-28 at 10.20.15.png

Slightly confused by the 750mm minimum from the outside wall. Is this an actual thing? Every stopcock I have ever seen has been secured to the wall in some way. My wall construction is solid block-work with insulated stud wall which comes to 342.5mm thick all in. This means the pipe would come up in the middle of the floor.

2nd question is if I use 32mm MDPE the minimum bend radius would be 480mm. Would I be allowed to use a compression elbow like the one in this link within the pipe lagging part after the footings so that it can come up closer to the internal wall?

Below Ground Elbow
 
Have a look for INSUduct fully compliant with all regulations no hole to dig under footings!
Thank you, I did have a look at this. I can't see them doing a 32mm unfortunately but not a deal breaker. The issue I have is that this is a listed building so anything visible outside like this would need to go through Listed Building Consent. (i.e. painful and slow)

My bad. Just seen the 32mm INSUduct External Water Supply Protection - https://store.jdpipes.co.uk/insuduct-external-water-pipe-supply-protection-box/
 
Tbh I wouldn’t want fittings below ground unless you really have to also use some 4” drain and long radius bends to sleeve it into your house
 
We have used them on listed properties by finishing insuduct just below ground level then core drilling at a angle from inside to meet it.
We use 110mm core hole correct insulation then foam fill.
I might be missing something but I don't really get the benefit? You would still need to core drill, just one system slightly higher than the other. They also don't seem to make the 32mm hockey sticks so would force me to use 25mm.

The other problem is that the building where this is going to be is 40cm higher above ground level than the other part of the house so I don't think I would be able to achieve this without some of it being visible.
 

Or

 

Similar plumbing topics

    • Like
  • Question
All sounds good the insuduct is a nice bit of...
Replies
15
Views
4K
  • Question
Does a magnet stick to the pipe?
Replies
4
Views
3K
L
  • Question
Please check the problematic faucets after...
Replies
11
Views
3K
  • Question
Hi everyone, i need a bit of advice, i live in...
Replies
0
Views
1K
  • Question
Here are the temperatures and kill times...
Replies
23
Views
4K
Back
Top