Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Ufh to y plan with upgrade to s plan in the Water Underfloor Heating Advice area at Plumbers Forums

Messages
4
20220705_104623.jpg
20220705_093223.jpg
20220705_093213.jpg

It looks like I have 2 options. The first uses the existing pump, the second uses another pump to pump water exclusively to the ufh manifold and pump. I have already taken off a separate flow and return from the top of the boiler. I would like to know which would work best. Any advice welcome. Thanks, Peter
 
Use existing pump and 3 - 2 port valves (S plan plus)
You would create endless wiring issues with extra heating pump requiring relays ect.
In a ideal world cylinder return should be last connection before boiler.
 
Thanks for your reply Murdoch. I am just trying to figure out the best way of wiring it as we speak. I don't have a firm idea yet so any suggestions would be very welcome. I have a probe to regulate the ufh water temperature to 27 degrees and a programmable stat to take the probe and room temperature can be enable on it as well to control the zone valve and boiler. I am looking at how this will work with the draton twinzone box and existing thermostat which I was going to reposition upstairs.
 
Hi all, since I have a Wunda manifold, roomstat and probe with a grunfos upm3 pump, I am going to follow the Wunda wiring diagram which makes it straight forward. The system will be based on the 1st option above,as Exadon2 pointed out, having an extra pump to control would lead to other issues. Pete

20220706_141730.jpg
 

Similar plumbing topics

Your sacrificing your kop to run that the heat...
Replies
6
Views
1K
Behind the control panel the cylinder unit...
Replies
7
Views
1K
Anyway, you can always increase the boiler...
Replies
16
Views
1K
not sure if it would or not, but already...
Replies
8
Views
1K
  • Question
Take the advice of whoever actually is there...
Replies
16
Views
4K
Back
Top