Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Leaking Hot Feed to cloakroom hot tap. in the General DIY Plumbing Forum area at Plumbers Forums

Messages
17
Hi,

I've noticed a slight weeping from the hot feed to my cloakroom tap.

Does anyone know how this seals? Is it a rubber gasket between the different coloured metals?

Not taken it apart as would need to partially drain the hot tank before doing so.

The Hansgrohe instructions suggest that the builder has not used the original Hansgrohe fitting (flexi pipe) as it suggests the small knurled end of the Flexi pipe should be a 9mm nut. It isn't.

The weep usually happens after the mixer has been used.

See attached image. Weep is where the red marker is.

Thanks
 

Attachments

  • IMG_20220722_203136.jpg
    IMG_20220722_203136.jpg
    277.5 KB · Views: 19
The brass fitting is a 3/8” MI to 15mm compression .

Between the flexi and the brass there will be a rubber washer, it may be captive in the flexi. First thing to try is to just nip it up a bit.

Although looking at the photo again it looks as if the water is actually coming from the compression end of the fitting and running down to your red mark. With two spanners try tightening the compression end.
 
Thanks for the response.

The nut size on the brass section appears to be around 24 - 25mm. The Flexi nut according to the Hansgrohe instructions is 19mm which seems about right (although as mentioned above it appears it might not actually be the OEM flexible pipe from the tap that has been used). It's difficult to measure both accurately with what I have.

I did wonder if the brass section was leaking myself but it does appear if I use a small piece of toilet roll paper to check the water appears to be between the bright silver coloured fitting and the brass fittings and not in-between the brass nuts which is where the drip does appear to form.

I did try nipping it with adjustable spanners but it hard to feel it so will try and source the correct sizes to do it properly.

Thanks again.
 
Actually you might be right. I might try and find a plumber to have a look as I really don't want to cause more damage lol. If I can find a plumber for such a small job. 😬
 

Attachments

  • IMG20220723101722.jpg
    IMG20220723101722.jpg
    187.9 KB · Views: 13

Similar plumbing topics

  • Question
To ensure a durable, leak-free connection for...
Replies
2
Views
407
  • Question
if you put an Allen key down from the top side...
Replies
5
Views
1K
  • Question
You may find some orings that you can replace...
Replies
3
Views
4K
  • Question
Thank you so much. I am now officially out of...
Replies
22
Views
3K
  • Question
Hello Shaun, Please accept my apologies for...
Replies
2
Views
2K
Back
Top