24mm 1/2 drive socket | Plumbing Tools | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss 24mm 1/2 drive socket in the Plumbing Tools area at Plumbers Forums

Messages
10
Hi, the 15mm pipe work to my shower use compression fitting, the elbow joint which is in the wall and the pipe comes out and in to the shower is lose and water has been leaking in to the clinker wall. is there a deep socket size 24mm that i can use to retighten the compression nut ? as i can’t use a spanner many thanks
 
Other lengths and brands available!
You would need to check that the internal bore is actually wide enough for the pipe for its whole length!
Amazon product
If you are trying to tighten the compression nut, but unable to hold the fitting itself because it's buried in the wall, there's a risk of bending the feed pipe and upsetting the other compression joint on the elbow, so a further leak. Can you get to it from the other side of the wall? 🤔

Edit - Ric2013 has the right idea - box spanner - much better! 👍
 
Last edited:
Hi the nut is in the wall so can’t get a spanner on it, the socket has to be long as there is about 4” of pipe coming out the elbow which goes into the shower cheers

Box spanner may be better? Box Spanners and Wrenches - https://www.primetools.co.uk/product-category/spanners-wrenches/socket-wrenches-and-box-spanners/box-spanners-and-wrenches/
 
If you are trying to tighten the compression nut, but unable to hold the fitting itself because it's buried in the wall, there's a risk of bending the feed pipe and upsetting the other compression joint on the elbow, so a further leak. Can you get to it from the other side of the wall? 🤔
True!
 
Still can’t see how a socket would be able to work on this, with pipes attached:
 

Attachments

  • 1667421651380.jpeg
    1667421651380.jpeg
    5.3 KB · Views: 26

Similar plumbing topics

S
  • Question
If it was on a job of mine I would cut it out...
Replies
1
Views
636
  • Question
So have started fitting all the bits together...
Replies
15
Views
2K
  • Question
Umm, I've just been to check on the pipes and...
Replies
3
Views
1K
  • Question
It's a solder ring fitting. If you use it then...
Replies
1
Views
742
    • Winner
    • Like
  • Question
What a great and informative post! Thanks for...
Replies
1
Views
887
Back
Top