Multiple Sinks on horizontal branch? | Bathroom Advice | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Multiple Sinks on horizontal branch? in the Bathroom Advice area at Plumbers Forums

Messages
1
Long time listener, first time caller.

I am finishing my basement but the one area I lack confidence is plumbing. I am looking to verify if what I have planned is acceptable. Framing is complete - The bathroom wall shares a wall with a wet bar on the other side.

I have a 2" stack coming from the basement slab and plan to have a urinal, bar sink and bathroom sink on this line. I plan to run a 2" line to the Kohler urinal, and a shared horizontal drain line for the bar sink and bathroom sink. I have quickly sketched a drawing (using square, not circular pipes - sorry) and will use all correct fittings and slopes - However - is there an easier way to vent instead of using 2 vents on the sink branch?

The distances are 48" from bath sink to bar sink and then 48" from bar sink to main stack. Could I have a vent between the bath and bar sink (42" for 1.5" pipe) if the bar sink is technically downstream from that vent by a foot or so? I have read and read and cant find the rules for upstream vents so im not sure if its assumed that the 42" to vent is ok or not?

Anything else I should be aware of?
17.5" for urinal from floor to drain
Bathroom plumbing.png

18-20" for sinks
Vents will all be 8' or higher to tie into main vent before a horizontal
reducer from 2 to 1.5 on main drain stack.

Thank you in advance!
Scott
 

Similar plumbing topics

  • Question
Hi All, Could use some valued help redoing a...
Replies
0
Views
663
Hello. I am planning to build a small half...
Replies
0
Views
506
  • Question
Hi Welcome! Could anyone offer their advice?
Replies
1
Views
501
  • Question
Have you tried something like This ?
Replies
6
Views
1K
  • Question
Hello. This is my first ever post asking for...
Replies
0
Views
919
Back
Top