Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Heating issue but hot water works in the Central Heating Forum area at Plumbers Forums

M

Mr Andrei

I've got a heating boiler which heats up the water in a tank located in a cupboard upstairs and then from there I get hot water & hearing. I get hot water ok but the heating doesn't come on when turning the thermostat to a higher temperature. I've got a 2 way motorized diverter valve which would out the heating on when I push the leaver to manual mode so I've changed the motorized unit on the valve but the heating still doesn't come on. I have also changed the thermostat and that made no difference either. Any ideas of what else could be the problem here?
 
You need to use a multi meter and work your way through testing all the switches work in the right order. they should all read 230-240v if they don't then it will be that component

Fused spur live to earth
programmer live to earth
Programmer switched live for heating to earth
Room thermostat live to earth
room thermostat switched live to earth
zone valve brown cable to earth
zone valve grey cable to earth
Zone valve orange cable to earth

Make sure your programmer is calling for heat and your room stat is turned up to the max.

If you're not competent to work on electrics then get someone in to do it.

1697235110548.png
 
The power to switch the boiler on for heating comes from a microswitch in the diverter valve head you have replaced. Maybe the diverter valve itself is stiff and won't allow the motor to turn it sufficiently. If you take the motorised unit off the valve and call for heat, does the head operate the microswitch and make boiler run?
Otherwise perhaps there is a fault with the thermostat or programmer?

or as above - fowlerboi who beat me to it has has good advice!
 

Similar plumbing topics

Are you Gas Safe Registered? If not please...
Replies
2
Views
536
Replies
8
Views
770
Heating will run until hot gets up to...
Replies
1
Views
897
A
Not sure why you’d replace the pcb without due...
Replies
1
Views
844
Deleted member 120897
D
So, (Lever on Auto) does HW work on its own...
Replies
14
Views
2K
Back
Top