Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Solid fuel back boiler decommission in the Boilers area at Plumbers Forums

Messages
3
Hi
We have a vented oil-fired heating system with a coal fire back boiler, this is going to be changed to a sealed pressurized system tomorrow and I believe, they are decommissioning the back boiler.
I have only discovered today there is no access to the water jacket, so will it be good enough to just to drain and disconnect the pipes and leave the pipes open, so no pressure can build up when we use the fire?
 
There has to be some part of boiler showing that's how they get hot!
Clear pictures of what you have would be useful.

How works is not the point as such, but here is a picture how the system works at the moment.
Apparently as we are changing to heat pump witch works on a pressurized system like a combi boiler it is not possible to have a back boiler as well as the can not work with a pressurised system.
If you do not disconnect them right the pressure builds up when you light a fire and they explode!
 

Attachments

  • back boiler pic.jpg
    back boiler pic.jpg
    88.4 KB · Views: 29
You miss my point
If you have a open fire with back boiler (or a wrap round boiler Dunsley type) the boiler has to be exposed to fire to work.
Thus easily accessed to drill holes in it or whatever.
 
Last edited:
By regs if you are going to continue using the fire then it should be removed.
In reality pipes are cut back as far as possible and the back boiler drilled. Light a fire and you will get some steam as the remaining water is boiled off.
 
By regs if you are going to continue using the fire then it should be removed.
In reality pipes are cut back as far as possible and the back boiler drilled. Light a fire and you will get some steam as the remaining water is boiled off.
Ok, thanks, so if it can not be accessed from the back they can drill from the front?Or would leaving pies uncapped be ok?
Als do you know why it can apparently not work with a pressurized system?
 

Similar plumbing topics

Thanks mate. Been very lucky, a neighbour...
Replies
3
Views
2K
Original reply deleted because I misread question.
Replies
1
Views
994
I once had a similar experience with my old...
Replies
6
Views
857
L
I can see the small leak in back boiler, have...
Replies
0
Views
564
LyndaB
L
Back
Top