Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

How well does bunging the cold feed and Open vent work

Matt0029

Gas Engineer
Have a radiator to swap. I'm thinking of piping back to the current supplies. The rad is slightly smaller. The connecting on the the old pipes at the end one by one. Would using bungs in the open vent a cold feed create enough of a vacuum for me to do this? Which a drain down. Thanks
 
It can work OK but it depends on the system. You will know pretty quickly whether it is going to be successful or not.
It is worth a try but I wouldn't mess about for more than 15 minutes, if it is not slowing down to what you would experience on a sealed system by then, leave it and drain it or freeze it.
Only my opinion from my own experiences.
 
Ended up being a one pipe system 😩. I froze it on each leg with the rothenberg turbo electric freezer. Was to be able to solder around 30cm away on. Put a wet grab between soldering area and freezer.
 

We recommend City Plumbing Supplies, BES, and Plumbing Superstore for all plumbing supplies.