Riello rdb 1 brandnew retro fitted to a firebird 70-90 | Oil and Solid Fuel Forum | Plumbers Forums

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Discuss Riello rdb 1 brandnew retro fitted to a firebird 70-90 in the Oil and Solid Fuel Forum area at Plumbers Forums

Inverness

Plumbers Arms member
Plumber
Gas Engineer
Messages
715
Fitted a new riello 1 rdb the noz zle that came with it was a .6 80 eh but no settings in the manual what it should be??
I got the CO2 at 11.6
Oil pressure 100
Any advice?
 
What boiler manual say? And the burner I linked to earlier or a different brand one
 
Rdb 1 burner. But it didn't say anything about the nozzle that was already in it.

Swap it to the one Recommend/ set kw in the boiler manual
 
Rdb 1 burner. But it didn't say anything about the nozzle that was already in it.

The maximum pump pressure (Kerosene) is 10bar (145psi) and minimum 7.0bar (102psi), my Riello G5X pump pressure is 8bar, 8bar gives 7% more fuel (vs 7.0bar), 9bar gives 13.4% more.

1728245264691.png
 

Similar plumbing topics

G
I’m assuming you’ve removed the two Allen...
Replies
2
Views
949
Replies
30
Views
6K
Thanks everybody for your advise. Will call...
Replies
8
Views
5K
A simple thing i'd probably check is the...
Replies
9
Views
1K
hi, no current pipework in concrete i believe...
Replies
7
Views
1K
Back