Evening all.

I'm doing a new build house that's out in the sticks so they have chose an oil boiler.

After discussing location with them and agreeing to this, they have moved the tank 70 metres away from where the boiler is going.

Due to this distance it's saying I need 12mm copper for the oil line to the boiler. Does anyone know where to get coils of this from as I can't seem to find it, or if there is another solution.

Boiler is a Worcester Danesmoor utility system.

Cheers.
 

Attachments

  • Screenshot_20241112_204655_Samsung Notes.jpg
    Screenshot_20241112_204655_Samsung Notes.jpg
    496.9 KB · Views: 11
Or tiger loop it

Should be good for 100m then if I remember worcesters table
 
Would you say 10mm will be ok then???

The oil tank will be higher than the boiler aswell.

Cheers.

Yes providing you fit a deairator
 