Hi all. Could someone help with a issue I have been having with my vertical radiator. I have one vertical radiator in my bungalow and it does not heat up unless the surrounding radiators are shut off. I have tried turning the surrounding radiators down but the have to be completely or very nearly off for the vertical one to heat, leaving the surrounding areas cold

Any suggestions on house to address this issue?

Many thanks
Paul
 
Have you tried balancing the other radiators?
 
Yes the rest of the radiators are working fine. Just the one vertical
I have a similar problem. Have fitted four verticals (1.6m x 0.5m) with two in one room on same run. Can only ever get one of the two hot and if I adjust them the hot one goes cold and the cold one hot!

Am thinking of increasing some of the pipework to 22mm with just 15mm spurs to the actual rads. Would this make any difference?
 
I have a similar problem. Have fitted four verticals (1.6m x 0.5m) with two in one room on same run. Can only ever get one of the two hot and if I adjust them the hot one goes cold and the cold one hot!

Am thinking of increasing some of the pipework to 22mm with just 15mm spurs to the actual rads. Would this make any difference?

What’s the existing pipework ?
 
What’s the existing pipework ?
Hi, Sorry for delay but decided to draw a plan of layout. From Boiler it's 28mm running into 22mm down centre of property (all on one level). Then into 15mm for feeds to rads. Originally in lounge there was just one radiator behind hall wall. I replaced with two vertical rads the furthest of which is about 8m from 22/15mm transition. Its this run I am thinking of increasing to 22mm.
 

Attachments

  • Heating System.pdf
    182.5 KB · Views: 65
So the longe two don’t heat up what about the utility one on the same run ?
 
Only one of the two in the lounge heat up significantly (the other gets mildly warm). The utility one seems to heat up ok but this not a vertical radiator.

So both lounges eg back to back have issues ?

And the flow and return go into the correct port of the rad as it matters on
Verticals
 
So both lounges eg back to back have issues ?

And the flow and return go into the correct port of the rad as it matters on
Verticals
To be clear, we only have one lounge and it has two vertical radiators. I seem unable to get both radiators to heat up sufficiently. If I close down very slightly the hot one, then it goes just warm and the other radiator which was previously warm gets hot. So never are both at the full level of heat.

Yes they are conected the right way. They had 'in' and 'out' stickers when purchased.
 
Have you tried balancing the other radiators?
Some of those Verticals Rads Have the Flow and Return are on Different ends Try and find out the make of your Vertical Rad is get on to the manufactures they will tell you what way it has to be piped weather the flow is on the left or the return is on the right the manufactures will tell you this . I have come up with this issue before this is the reason why i would suggest talking to the manufactures . Try and Balance the heating throttle down the Return on all Rads . I would say all the connections to all rads are dropped down from the Attic if its a Bungalow with concreate floors or if you have wooden floors all pipes are under the wooden floor. Some clowns in The Plumbing and Heating Industry use 15mm to service four or possibly five rads this is no good You need 22mm pipe up to the last radiator then the 22mm can be reduced to 15mm to feed the last Rad . Some Plumbers use 20mm Multilayer pipe in place of 22mm copper when in fact they should use 26mm or 25 mm Multilayer Layer pipe . But it is starting to get cold now and you need heat but reading between the lines i would say The flow is were the return should be failing that it could be a flow issue but if you have to knock off all rads to get the vertical rad to heat that is just BS . Get the Contractor back who ever installed your heating it should be under warrantee
 

Similar plumbing topics

  • Question
It’s expansion and contraction do you have the...
Replies
1
Views
589
  • Question
The reseller ignores UK regulations about...
Replies
16
Views
2K
  • Question
The other bedroom is one of the kids rooms...
Replies
4
Views
365
  • Question
Thank you so much your very helpful