Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    S-traps self Syphoning

    I watched a video and it went in about S-traps self spyhoning after discharge and said they were band in the USA. This isn't the case in the UK?
  2. M

    Isolation valve with double check valve

    The isolation is usually ok in these?. Have been to some probably cheap filling loops that leak from the on/off lever when used.
  3. M

    Isolation valve with double check valve

    Thanks means 2 less compression joints on an outside tap installation. I don't think many merchants stock them ? Haven't asked yet but just seem online
  4. M

    Isolation valve with double check valve

    Does anyone fit these internally for outside tap installation? Instead of an isolation valve and a separate double check valve.
  5. M

    Viva full valve double check valve

    Do these fill valves have a double check valve in the tail? Seems to imply it in the technical.
  6. M

    Rigid syphon

    Thanks are the viva syphons any good?
  7. M

    Rigid syphon

    Im looking at it. If put a Dudley in would I be able to remove the yellow pin to split it? As the front of the syphon looks close to the cistern.
  8. M

    Rigid syphon

    No it wouldn't would be best to replace with a Dudley 3 part one or just an adjustable height one.
  9. M

    Rigid syphon

    Hi just to confirm does this look like a rigid syphon. Not seen in person but doesn't look like it one of the ones that splits so can replace the diaghram. Thanks
  10. M

    Mulitquick concealed cistern

    Sort of just after a temporary fix as there having a new bathroom soon
  11. M

    Mulitquick concealed cistern

    If I take the cistern off and take the syphon out would any 1.5inch syphon washer fit to seal it. It's leaking through the seal were the syphon sits on the cistern. Tried tightening in place no look.
  12. M

    Mulitquick concealed cistern

    Has a leak were the sphyon sits in the cistern
  13. M

    Mulitquick concealed cistern

    Any one know if you can still get syphons for these concealed cisterns
  14. M

    Inline potable expansion valves

    Are they just called flow through valve expansion vessels
  15. M

    Inline potable expansion valves

    Do they have a specialist name? Going to have a look at them
  16. M

    Inline potable expansion valves

    Has anyone fit inline expansion valve on the cold water supply to an unvented cylinder. The normal style were you just tee of after the composite valve can leave a dead leg in the pipework? A local water authority has pulled some. Thanks
  17. M

    Heat pump hot water cylinders

    Has anyone fit the hot water cylinders with a little heat pump on the top that has ducts to bring inside and outside air in to the unit. Piping up wise is it just the same as a normal direct cylinder?
  18. M

    How well does bunging the cold feed and Open vent work

    Have a radiator to swap. I'm thinking of piping back to the current supplies. The rad is slightly smaller. The connecting on the the old pipes at the end one by one. Would using bungs in the open vent a cold feed create enough of a vacuum for me to do this? Which a drain down. Thanks
  19. M

    One pipe system condensing boiler.

    Would a one pipe system work efficiently on a condensing boiler as the return type would likely be below 54c all the time. So the boiler would run in condensing mode. Alot of condensing boilers don't run in condensing mode.
  20. M

    Testing zone valves electrically..?

    Can you test zone valves electrically to find out what may be at fault?