Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    heat line vizo24

    />>>>>>>///////////?
  2. D

    baxi 80e

    if when checking the gas valve for correct operation,am i to check for 240v as the boiler goes through it's sequence,or with the power on and test for 240v as the boiler is idle,hope you understand at what i'm getting at
  3. D

    fixing a basin

    best way to fix basin to stud wall...?
  4. D

    no hot water

    the punter said the boiler was not working as i have no hot water up stairs ,heatline vizo ,i ran kitchen tap no problems,went up stairs ran shower i decreased flow rate and shower was getting hot all of a sudden there was a screech and the shower ran cold, same on basin as i reduced flow rate...
  5. D

    solid flue fires

    when the twin wall selkirk leaves fires flue and enters a class 1 does that joint need to have an inspection hatch
  6. D

    worcester 28 cdi

    what a nightmare,i changed the diverter valve the bypass would not go far enough into filling loop enabling me to put the flimbsy piece of u shaped rod to lock it in,next the water to water heat ex the top right hand fixing i give it one turn to many and the screw snapped leaving the threaded...
  7. D

    good cheap reliable boiler

    i'm after a combi for the rental market any suggestions
  8. D

    alpha cb he 33

    can i move pump head and change diaphram in situ
  9. D

    no hot water

    i have a baxi105he the hot water only works when c h is on, and a alpha cb 33 according to punter they only get hot water when th ch is on and turned up on stat to 21 degrees ? any ideas
  10. D

    potterton suprema 40

    gas pressures fine but poor temp even when on max,any reason other than blocked dirty heat ex ?
  11. D

    semi recessed gas meter box

    when the gas pipe leave gas box at the rear into property the pipe work is supposed to be sleeved, or are these box so designed to act as a sleeve and as long as they are sealed at both ends,every thing is fine.
  12. D

    baxi floorstander

    when you call for heat either dhw or ch ,it takes a while and then the boiler explodes into action with flash of yellow engulfing the entire bottom of boiler,seals and ventilation seem fine flame picture,yellow flames any ideas, boiler recently serviced not by me.
  13. D

    worcester 24i

    problematic over heat stat,every now and again it will trip out,whats the likely cause.
  14. D

    vokera compact 29kw wiring

    i'm wanting to wire a danfoss tp5001si rf to this boiler,but the connection for room stat 24vdc,the mi are limited and electrics not my strong point.
  15. D

    odd size baths

    does any one know of a goo d odd size bath supplier.
  16. D

    mini c24 expansion vessel

    the vessel needed changed,so rather than boiler of the wall i put a remote one 8ltr on the return as close to boiler as possible,but the boiler still increase pressure and setting prv off, i felt remote vessel and it was just warm it felt as no water was in it, if that makes sense,whats going on
  17. D

    glowworm swift flow 80

    burner will light but wont stay on no aps and not sure if fans running
  18. D

    baxi 105 he fault

    flame failure, condensate blocked 30 fault light comes on,pump runs fan runs one click,then back to fault light,the hot water was working until i worked my magic and that stopped working aswell the hot water indication light does not even come on when taps running
  19. D

    2 port

    is the connection made when you use manual lever on valve,or does it energise and take it about 10mm to micro switch,i've took the top of this one and when i use lever it's about 10mm short from micro switch,when iv'e used 2 port in the past the manual lever opens valve,but is it energised that...
  20. D

    2port valve

    the valve seems to be stuck, when heating is called for it does not engage micro switch,i started to loosen head screws and the valve seem to release and engaged micro switch,,will i get away with changing just the head or is valve body causing it to stick