Search results | Page 2
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    ideal isaR FAULT CODE e 8

    anyone know what this is
  2. D

    baxi 105e leaking

    from the diverter manifold were it connects to the dhw pressure diff valve ,can you get a kit for the diverter valve or will it eed replaced.
  3. D

    fitted kitchen appliances

    i am having a problem with my pipework,both mains and waste water pipework,the washing machine more or less goes back to the wall and i'm suppose to get a stand pipe behind it, i mean surely the manufactures know ,with fitted units either side and 60mm from wall to units back panel,any ideas
  4. D

    gas leak

    i have been to a gas leak and can not find it,with appliances isolated ,the leak is on the pipework and quite significant,what is one to do,i'm back tomorrow to tackle the kitchen floor,i didn't no that you could get 22mm copper pipe in 5mtr length, i do now,lifting flooring every meter looking...
  5. D

    valiant ecotec

    this combi has a rf drayton stat,when you call for heat every thing appears fine,at the receiver all seems fine but at the boiler there is no call for heat as the boiler is giving the code s 30
  6. D

    will you install the gas pipe work and commission boiler

    thats the phone call i've just had, where do you stand on this,the customer has done all the other pipework.
  7. D

    vaillant vcw sine 18

    does anyone know how to take gas inlet pressure on this beast of a boiler and gas valve.there is a test nipple on the gas inlet pipework buts it's behind the boiler and impossible to get at..or is it..and i'm after the manual.
  8. D

    combi - combi changeover

    pretty straight forward apart from the gas,,boiler at back of house,meter at front a stair case in the middle of two bedrooms,the current gas pipe goes into concrete floor in 22mm and reappears at the boiler in 15mm,any band a combis that are suitable for 15mm supply,if i take the gas pressusre...
  9. D

    raven heat csi 85 a

    works ok in dhw, but when ch is called for the boiler fires burns for approx 5 seconds then shuts down, then fires burns for 5 seconds then shuts down,it does this as long as you call for heat,the flow pipe is red hot and the return is barley warm,when the boiler is calling for heat and you run...
  10. D

    pressure loss

    at meter 20mbar- 5mtr of 22mm - 3 elbows - pressure at boiler inlet 18mbar,am i to assume i'm losing it through the boilers gas valve to inlet point,
  11. D

    flue box

    can you connect a flexi liner direct to box,if you can how do you fit a 5 inch liner into mf10 vent on top of flue box ,what a mission, is there a knack
  12. D

    under floor board vent

    the mi asks for a vent of 15cm2, so if going under the floorboards to an outside wall does that make the floorboard vent 22.5cm2
  13. D

    down draft in a class 1 flue

    how does one reduce the down draft, went to a job today were the down draft filled the room
  14. D

    flue box connection

    can you fit a flexi liner or do you have to use a rigid to flexi connector first.
  15. D

    outset gas fire

    i 've taken a back boiler out connected to a pre fabricated flue,the connection from the bbu hood was selkirk twin wall ,this part fell away when i pulled the back boiler out,what is the best way to make good,with an out set ,closure plate etc,the builders opening is huge.
  16. D

    potterton sumprima 30 - 80

    went to this today because it is over heating and pumping over badly,indirect cylinder,3 port,cold water tank with vent pumping over from hot water vent,not a sealed system no expansion vessel gauge etc but no vent from heating side am i missing some thing
  17. D

    connect copper to iron gas

    i think the iron is 20mm not sure what sizes does iron come in,i need to connect 22mm copper what do you use....?
  18. D

    blocked 10mm plastic pipes to rads

    tried mains pressure water,a foot pump,blocked any idea's cause it got me.
  19. D

    back boiler gas fire unit b.b.u.

    when removing gas fire back boiler to replace,do away with back boiler and renew with a new fire,can the liner remain.
  20. D

    eless sapphire double feed indirect hot water unit

    rads getting hot when hw only is asked for....and a builder put a pump under the bath to increase pressure to shower not sure about this as it seems to be drawing water quicker than the unit can deal with any body came across a similar set up and does it work.?elson sapphire
Back
Top