Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    worcester greenstar 30 si

    customer left filling loop conected as the boiler was losing pressure,i was called in and when i got there the filling loop was connected and on, filling the boiler,but rather than go out prv it was going through the boiler and coming through the condensate trap,the only explanation for that was...
  2. D

    radiators placement

    why is it common to see radiators placed under a window, does it improve convection,is it cosmetic...?
  3. D

    baxi 105e

    every time you call for heat or dhw the boiler trips the electric,the hydraulic diff switch does not seem to be working,and would a jammed pump cause the boiler to trip electrics in this manner
  4. D

    probe wanted....!

    i have a kane 455 fga and i am after a suitable probe for gas cookers,and where can i find co/co2...ratio levels for cookers etc.
  5. D

    alpha cb 33 he

    does anyon e know if primary sensor is in a pocket or is it a drain down,ta
  6. D

    baxi duo tec

    when in ch mode the boiler will fire on full rate for 30 seconds then go out for say a minute then fire again..it does this constantly,dhw is ok.as any body came across this before with this model,inlet gas pressure fine.
  7. D

    working pressure at meter

    18mbar.............at meter .....working pressure on boiler fine....is all ok....!
  8. D

    worcester greenstar 24 & 28 i junior.

    i am finding that when doing services on these boilers, the co2 % levels on max and min always need adjusted, are you finding this or is it just me
  9. D

    gas fire's

    what would you class, not been able to access the builders opening when doing a landlords cert on a gas fire,i'm sick of fires been glued,sealed into position,i have to date just been noting it on cp 12,but unsure if i should be doing more ....?
  10. D

    ferroli modena 80 e

    i got called to this boiler as it was not working,i went in called for heat,pump ran and nothing else,i ran the hot water tap pump ran, nothing else, so i take the cover off and room sealed cover and the boiler fires no problem in both ch ,dhw,gas pressures fine venturi clean,serviced....?
  11. D

    baxi instant 105 he

    i changed the exspansion vessel and when i put it back together it leaked from the pump the plate ex and the secondry heat ex,whats the best way for these connection on the secondry heat ex the boiler plan shows o rings but mine had none ,i tried some and it made no differrance,the pressure...
  12. D

    room stat or programmer

    calling for heat on a open vent indirect heating system,gravity hot water ,pumped heating,when the punter calls for heat by the room stat she gets nothing, but at 2 in the morning the heating will fire up the clock is set correctly and the programmer is set to come on at 6 o'clock,i'm thinking...
  13. D

    price please

    take out old bathroom suite,strip all four walls of tiles,make good wall bonding etc,tile 14m2,replace bath, close coupled toilet,basin pedesal,panel ceiling.
  14. D

    price please

    can you give me a rough idea how much you would charge for a new heating system in a 3 bed semi detached house, baxi 28kw duo-tec clock flue 7 rads 1xtowel rail t.r.v,s rf room stat (programmable magna clean 30mtrs 22mm copper pipe 30mtrs 15mm copper pipe fittings, inhibitor etc conseal were...
  15. D

    wiring problem

    fully pumped system, mid position valve,i can not get the heating to work when called for by programmer and room stat, it will only work when heating and hot water are called for. the pump ,mid position valve and cylinder stat are wired to a wiring centre and the room stat is wired to the...
  16. D

    baxi 80 e

    runs ok gets to temp then knocks off,cools down then does it again
  17. D

    ideal standard basin

    does anyone know were i can get my hands on dissccontinued lines,namely a pink bathroom basin 1 tap hole.
  18. D

    mystery pressure loss.

    baxi duo tec combi he, 24kw, losing pressure, filling up every other day,no obvious signs,any ideas.
  19. D

    worcester 24i

    i was pricing parts for this relic and could not believe the price of a mechanical clock £71.50 at my local parts retailer and the price of a isolating valve,(ch pipework to boiler iso valve),£16.40...it is leaking from the slotted centre were you open and shut them,annoying.also plastic facia...
  20. D

    pipework lay outs

    can you have more than one return from the central heating return to the primary return and can it be place'd between radiator returns,open vented fully pumped.