Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    system nightmare

    the system is part one pipe,part two pipe,microbore,and blocked,i've been there two days now and it's getting worse not better;i have pipes running every were,it's a 12 rad system and the pump was pulling from the boilers return,the one pipe part had a manifold feeding 4 rads ....i know..!,my...
  2. D

    open vented fully pumped double feed indirect heating system

    ikon 60-80 ci,fanned flue boiler,this system is 10 rads and you are lucky if three rads are working to there potential,the cold feed from f&e is tee'd into return at cylinder coil and the heating vent is also on the coil hw feed,the system was pumping over all the time,so i changed the piping...
  3. D

    gas fire install

    installed a gas fire today and used pebbles instead of coals,the problem i had was black sooting on a nice clean white pebble.i did a bit of tweeking to no avail,what can one do ....?
  4. D

    immersion heater

    i cannot trace the power to immersion and the problem being that when tested with a multimeter i'm getting a reading of 110ac...whats going on
  5. D

    baxi 105he

    keeps loseing pressure,no obvious leaks,prv is as dry as a bone,nothing obvoius behind the cover,it's a mystery..any ideas.
  6. D

    mid position valve

    how would one expect the valve to act if there was no cylinder stat or any way of callling for h w only,
  7. D

    kitchen mixer taps

    were will i get cartridges for bristan stigma kitchen taps
  8. D

    gas pipe work in brick wall

    how would you class pipe work buried in bonding vertically up a wall
  9. D

    schrader valves

    can you fit in on vessel in situ,baxi 105he
  10. D

    baxi instant 105e

    i was informed the pcb have a anti cycle time delay,now the problem i have is when i call for heat at room stat it takes an age and some times not at all for the boiler to fire,the boiler radiator light comes on and the pump will run, when dhw is run the boiler fires as normal and when knocked...
  11. D

    condensation on toilet cisterns

    what causes this,(bad air circulation ?)..went to a house today and the condensation build up on the cistern was the worst i'd seen,the water temp is cold and the air temp warm is this causing or adding to the problem, he asked my advice and all i could come up with is for him to improve the air...
  12. D

    baxi instant 105he

    when heating is called for nothing ,but if i run the tap and the heating is still being called for when i turn the tap off it will switch to heating and work fine,but it will not hav it whn you call for heat, you have two valves on this model,ch ,dhw,
  13. D

    toilet seat

    how does one change the toilet seat on one of these back to the wall pan and is it possible to pad lock a 3 geared griffter to a torbeck with the float removed ?
  14. D

    baxi 80e

    intermittent firing problem,no running taps and room stat ok,going to have a look today any ideas,ta.
  15. D

    baxi combi

    hot water no central heating......!
  16. D

    water meter

    i had to remove a water meter to lag the incoming water supply, above ground level, within a cavity, should have been done when it was installed, but wasn't...?anyways when i replaced the meter i'd changed the arrangement and as a result i had to shorten the 15mm copper pipe so it would fit on...
  17. D

    soill pipe collar

    i have got a seperate cistern and pot connected by a flush pipe,i cannot change it to close coupled as the soil pipe connection is too far of the wall,were the pan connector connects to the soil pipe there is a big fat ugly pot collar, my question is can i cut this off,at ground level and what...
  18. D

    wiring problem ?

    i went to a back boiler,controled by a programmer and room stat ,pumped central heating and gravity hot water,the problem is when the central heating is called for at the programmer the boiler will fire but the pump will not come on unless the room stat is turned up above room temp,so basically...
  19. D

    new hot water outlet

    a friend of mine has put a basin right next to the hot water cylinder and says that he wants the basin hot water tap tee'd into were the hot water outlet is on cylinder,i'm under the impression and what i can remember there's a minimum distance before vent,i've seen piping arrangement to...
  20. D

    iron soil pipe

    came across these pipes in a block of flats,they have a threaded boss connections ,does anyone know were to get some sort of connection to revert back to plastic waste pipe