Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    ideal isar he 30

    if you want a boiler to keep you on your toes,frustrate you to the max,make you look like you don't know what your doing and contenplate a different career, then this has got to be a contender..
  2. D

    worcester 28 i junior

    it goes through its sequence full fan speed but will not fire, and after about 3 minutes fault lights blue on and off and refresh light about 1 beat per second, any ideas.
  3. D

    direct cylinder

    i went to a job were the immersion keep't blown,so the idea was to change it, not just the element the whole immersion, any ways the bloody thing would not budge and the cylinder started to buckle,meaning a new cylinder but when i looked at the cylinder there was two tappings on the side, but...
  4. D

    baxi 105e no pre heat.

    the boiler goes through the lighting sequence,sparks but will not allow any gas through,what holds back the gas on this model no mi
  5. D

    second hand boilers

    whats your opinion on builders wanting to use second hand boilers, do all the central heating pipework them selves and asking us(plumbers)to commission the boiler...?
  6. D

    saunier duval therm f35e combi

    on heat exchanger there is green scale build up and black markings on cover, would this be a split in heat exchanger causing a leak,and when doing combustion checks the mi asks for co% and ppm, my readings were no where near mi readings,but my ratio was well within limits,and trying to adjust...
  7. D

    joining soil pipe old to new

    whats the best solution regarding old metal (iron) soil pipe, when renewing sections,is there any thing suitable out there to join these sections together,i've came across them were the've been botched up and leak.
  8. D

    mid position valve wiring s

    the fuse keeps blowing so by a process of elimination i dicsconnected,stat, valve, boiler, clock, pump etc,in turn and when the pump was disconnected the fuse did not blow so one would think the pump was the fault,so i changed the pump and the fuse blew with a new pump and wiring, any ideas
  9. D

    cooker fault

    the by pass on main oven is fine,but it will not turn up,does that mean the thermostat is not working or is it the ffd not allowing gas through so is it that ,what is the best way to determine what it is, any thoughts
  10. D

    new coals for gas fire

    i am after a set of coals for a baxi model 751,(sorry thats all i've got), gas ilfe fire, is there a decent web page or any other idea's
  11. D

    worcester 28 si ii

    the boiler would from cold allow you to have a shower,then knock off with fault light flashing(fast)primary sensor is ok as are ch dhw,the boiler did however start to smell of burning so i knocked it off and i had to leave it as owner needed to go out i said i would go back later,i fear the...
  12. D

    baxi duo-tec 33 he a

    i am after a simple easy to use rf stat to bring system into line as punters use trv's to control central heating any ideas welcome
  13. D

    gas flue box

    i did a service on a gas fire,it had a closure plate and a flue box was used,my query is, 1, does the double walled chimney(liner)need to be accessible in it's entirety,like flues in voids, 2,the gas connection to the fire is outside the flue box(at front)is this allowed.. 3, would you expect...
  14. D

    worcester greenstar 28 i junior

    blue light flashing constantly, when hot water is called for the boiler fires ,there is no hot water going to tap it is all getting dumped down the flow,how do the diverters work on this model, i did get diverter motor to work a little bit but the water went down both hot tap and flow, am i...
  15. D

    max and min burner pressure

    when testing max and min pressures on gas valve,max is ok but when removing wire from valve to reduce to min and it justs stops at max,am i to assume the potinometer or what ever they are called,is not increasing and decreasing current to gas valve,i got 10 k ohms when slightly warm so ntc not,i...
  16. D

    sealed unvented systems advice

    would you put the expansion vessel on the heating sides flow or return,
  17. D

    2 port zone valve - 2 port motorised valve

    whats the differance, apart from price..?
  18. D

    vokera 24

    looked at one of these today and the air pressure switch has only one hose to it this is attached to fan,when switch is proved it modulates gas valve supposed to,but this is just reaching temp, knocking off, cooling down and knocking back on, any ideas,it also wont stay on if combustion cover is...
  19. D

    vokera compact 25

    goes through correct sequence burns for a while and knocks of, "punters description",they also said a plumber told them it was scaled up causing the problem, i am going on monday,i've only ever been to one vokera and i ended up changing that, so any pre knowledge you can give me regarding the...
  20. D

    from open to a sealed system

    i am to change a leaking indirect open vented cylinder for a unvented system, thhe current system is a mid position valve set up on a y plan, my understanding is ,you now have to have 2 x 2port valves to comply with regs and this is on a s plan,the position of the cylinder is to remain the...