Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. D

    gas rates on boilers

    when doing gas rates,my boss always told me to run the hot tap at full rate to ramp the boiler up to full rate, giving you a max heat input reading,so when you put the boiler in service mode is it working on full rate, ch or dhw or both the mi give different heat input figures always higher on...
  2. D

    electric shower

    all of a sudden it has lost pressure at shower head,incoming mains pressure fine,no flow restrictors fitted, any ideas my friends.
  3. D

    baxi platinum

    comments welcome,
  4. D

    gas safe inspector visit

    anyone had a visit lately,anything new to expect,got one on tuesday.
  5. D

    worcester junior 28 i greenstar

    done a flue gas analyser check on this model,got a reading of 0.0016 ,fan speed ok,heat input ok,i gave heat exchanger a clean,tested again got a reading of 0.0016, i phoned tech department up they said as long as ppm were below 200 ,and this reading shows that they were, they said alls ok...
  6. D

    sime boilers

    are they any good,whats installation like and after care
  7. D

    spillage on gas fire,owner says its nothing

    having done a boiler service,i gave the usual visual on the other gas appliances,duty of care and all that , this is a house split into two flats up stairs and downstairs,noticing the black sooty marks on the top fire, i asked when it was last looked at, this is an elderly forgetfull owner who...
  8. D

    fully qualified plumber in two weeks.

    have these so called plumbers damaged the industry,a straight YES or NO answers only,i have heard all the arguements ,some are genuine,hard working,good etc.it would be interesting aswell if you stated if you are an apprentice, qualified n.v.q level 2 & 3, or a fast tracker. my answer :YES...
  9. D

    ideal isar he 30

    i;ve got no power to the boiler,external fuse fine,i noticed water pressure was very high when cold, no mi , i was wondering do these have an internal reset button or an internal fuse that would go first,any ideas.
  10. D

    direct hot water combination ccylinder

    has anyone came across these cylinders the problem being there is no water in top part,cold feed tank?.but i can still draw water off, at both cold and hot water taps,it is an old model 15-20 yrs?, there is two tappings at two thirds up what go into a t.m.v and then on to a shower, the hot is...
  11. D

    worcester junior 24 i flue gas analyser results

    i did a check on this boiler and i got a reading of .0009 and a co2 % of 10.3%, i looked in mi and it asked for a % of 9.8 but it did not give any parameters is there a method to work this out ,or does anyone know for this model is it acceptable
  12. D

    heat input or output

    when gas rateing an appliance ,modulating burner an old timer told me the final calculated kw outcome should be more in line with the mi heat output not heat input.
  13. D

    plastic air vent

    if you find a mesh type plastic open and shut air vent in a situation were it does affect combustion or flame picture,flueing etc,what would you do a.r or n.c.s.the situation i found it in was a back boiler, fire and the ventilation requirments were adequate other than the un suitable vent
  14. D

    spur or own elec supply to boiler

    can anyone clear this matter up for me,i was told of an electrician friend that all heating systems should have there own independent supply from consumer unit,i have and i'm sure many others have got the elec supply from a spur or even in some case put a 3 point plug 3amp fuse and away you go...
  15. D

    exspansion vessel

    why would you put one of those small shock absorber type exspansion vessel on the incoming cold supply to a combi boiler,water pressure not excessive,no unwanted noise prior to been fitted.any other reasons,please enlighten me?
  16. D

    kane455 flue gas analyser

    does anyone know how much it is to get these re-calibrated and how long do they take thanks
  17. D

    p.r.v.from combi boiler

    can the pipe work from the boiler go immediatly vertical
  18. D

    mini c24 combi boiler

    fires up for hot water when ch is ask ed for nothing,if running hot tap and asking for ch,when i close hot tap ,ch will fire for 10 seconds then knocks off,any ideas boiler now firing for short time in both ch and hw ,but after 25 seconds boiler lockout red light comes on,gas cut.
  19. D

    worcester 28 si 11

    fault on boiler red light flashing fast tested all heat sensors and air pressure switch all ok,but i have noticed on the circuit board one of the white plastic thin oblong box connection on left hand side of board at bottom flashes and clicks and fault occurs,how can i find what this connection...
  20. D

    worcester 28 si 11

    when i switch on it goes through the motions then fires ,it is ok for 3 min when flames seem to play up then it will go out and flashing light comes on (fast).it does this in both central heating and hot water.any ideas please.