Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    how many on a 15 mm pipe..

    While on holiday in south Africa we went to a restaurant in the Drakensberg. Spotted these radiant heaters on wall. 10 of them 7 kw each on a run 20 metre 15 mm pipe
  2. M

    power showers

    Good afternoon chaps. Anyone fit a particular model? Never installed one before so would like to recommend one that people have fitted and are happy with. Ta
  3. M

    commissioning boilers in a block of flats

    I have got a mate who is working for a plumbing company in a block of flats. Apparently there is 20 wb boilers installed that need to be commissioned. All gas carcass is track pipe and is all on show, and the boiler is the only appliance. All flues exit out of the wall. Would you commission...
  4. M

    worcester bosch 30cdi 2006 fan pressure

    I have been looking for the above online and I am getting 3 different figures. One says -3.9 another says -4.1and another says -4.5. Which one is one do I go by? I called the technical and he said as long as it is better that 3.9 it is all good. Do people agree with thats
  5. M

    danfoss Randall cp15 direct replacement

    I have this programmer which is knackered. Looking for a direct replacement that clips on to old back plate and also one you can have seperate times for heating and hot water. Cheers chaps
  6. M

    fastening threaded rod to brick work

    Evening all. I need to do the above. Now I have looked online at lots of different anchors but none that seem to be good for brick work. Drop in anchors are only good for concrete apparently. I am just needing to fit a few pipes and a flue so not really that much load on it. What about these...
  7. M

    WB system boiler wiring

    Hi chaps. Need a bit of advice on this. Taken out an old vokera system boiler and fitting a wb system boiler. The wb says in the manual that the switching part needs a neutral. So this will mean 6 wires from the wiring centre and into the boiler. I only have 5 from the old system. Is it...
  8. M

    brass crimps for electric terminals

    You know when you get a cable on a boiler that has the crimps on them, can you buy them? It is so much easier to put them in the block when they have these on. I have been frustrated enough doing it with the strands going all over the shop
  9. M

    radiator extension piece

    Anyone know of a good make that does not leak. I know it's pretty much a diy fix but the client wants it done this way rather than a drain down. They are behind raditor covers so won't be seen.
  10. M

    potterton ep2002 problem

    Ok, so the 3 port valve was knackered. So I change it. Now the only way I can have heating on is if the hot water 8 selected on the programmer. It will turn on and off with the room thermostat, and also stat on when the cylinder stat is satisfied. You can only choose the same times for both so...
  11. M

    What shower valve to replace this with...

    It has now been changed to a combi so need rid of this power shower. But, it needs changing without altering the pipework by removing tiles and so on. So a quick fix
  12. M

    WB 24i Junior fault

    What do you use as in a little connector to be able to get your multimeter to read the voltages. I couldn't get my prongs in the connector on the end of the fan. Any way, the fault I have is intermittent. The blue light flashes fast but with no lockout. It says in manual volatile fault...
  13. M

    boilers containing asbestos

    Do you guys still service them? Basically when it says it contains asbestos in mastic fibres. Where is this?
  14. M

    ideal plume kit 208179

    pluuuming
  15. M

    ideal plume kit 208179

    does it come with a length of pipe or is it just 2 elbows?
  16. M

    main plume displacement kit

    Anyone know if it comes with the standard flue as well? Some sites do say this and it costs £135 plus vat. So surely it must right?
  17. M

    Air or potterton suprima issue

    This system in hot water only seems to create lots air which I cannot get rid of. I have put air vents on both the flow and return connections on the coil but they don't help. The air seems to come round every minute or so and you will hear it really loudly. But what might be the cause is the...
  18. M

    ideal vogue 32 analyser readings

    I have just installed this boiler. Nice fancy user interface. In service mode in max rate I am getting O2 4.2 co2 9.5 Co ppm 129 Ratio .0013 Ratio and co is quite high. Usually when commissioning a new boiler I get a ratio of around .0007 and about 70 ppm co. Pipe...
  19. M

    How's this for a toilet.....

  20. M

    running new gas carcass.

    So, I need to run a new gas pipe around the side of a house to a new boiler. The old pipe goes under the ground all the way to the back of the house to boiler and oven. Is it okay to disconnect the boiler from this (as running new 28mm supply at side of house) and leave the oven on it? Or is it...