Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    a day in the life of a plumber

    Called to a job this morning, leak in the ceiling. Well washer in ball valve had gone so overflowing. So I turn get valve, it snaps, look for incoming main, find it the corner of a corner unit. I cannot budge it. All lead pipe so not going to try to hard. Try find main on the street, I can't. So...
  2. M

    biasi m96 irratic ignition fault

    So the above boiler is going through its sequence, flow switch, pump runs, fan, aps and lights. But as soon as it lights all power cuts out. It will do this 3 or 4 times and then works ok. It does it in both hot water and heating. But is very random. I had to turn the hot tap on and off for...
  3. M

    Ideal combi heating running constantly

    A client has sent me a couple of the above boiler. Once the heating comes on, it stays on. Am not sure what boiler it is but you guys will probably tell by the controls. It has a cm927 wireless stat to it. Are there common faults I should be looking for with this boiler? Stuck diverter valve...
  4. M

    mid position valve you think....

    Just had a call from a client, house has gone cold, no fault code on boiler. So I tell him to go upstairs and turn stat up on water cylinder and it fires. So then I tell him to put mid valve in manual until the morn. So, is it just the mid valve or shall I take a room stat with?
  5. M

    help with re-running a flue

    Happy new year guys!! I hope it is a prosperous one for all us plumb bums. I have been asked to re-run this flue. Is it possible to come up out of the roof and put a couple of elbows on it and run up the wall past the window?
  6. M

    Work in Walton

    I have just been sent a job to quote for in this area. Quite a big job including undefloor heating and drainage works. I have not done any drainage before so want to know if anyone would like some work. It will start towards the end of January. I have all the plans which I can email across to...
  7. M

    CON error on vailiant eco tec plus

    The pressure gauge says it 1.5 bar but the digital dial says 0 bar. So boiler is not firing up at all. Is this a new board guys
  8. M

    alpha cb 50 parts

    Went to this tonight and water has been pouring out of hesting side prv. Buckets of the stuff. So disconnected filling loop without touching the isolator and it was dribbling a wee bit with great pressure behind it. So diagnosis was filling loop left on and now prv knackered. I looked at the...
  9. M

    can you get reverse circulation on a 2 2 port heating system in a bungalow?

    I was installing a heating system where I was running the hot water circuit as the last T. He asked me why I was doing it and then said that that was only applicable if it is thermo syhoning and on a 3 port valve. I told him it had nothing to do with thermo syphonng but the pump pushing it. Does...
  10. M

    are motorised valve heads interchangeable

    Got a client who has a tower mid position valve wherd the gears are crunching like mad. Body is fine. So is it possible to just put a a honeywell or corgi head one
  11. M

    Thermostat problem...maybe.

    Ok a client of mine had a problem with an wireless drayton room stat. As said before on here, always easy to just replace first and see if it works. I changed the receiver and stat for the new drayton and it worked ok. And has for a couple of weeks. Then he said it would not come on if he...
  12. M

    funky basin???

    What a mission it was to take out. The frame was massive. I quite like how it looked but it was not practical at all. On the top where you see the 3 white pads, it had a black piece of glass about 5mm smaller diameter than the top. Now, what about these pipes below? What are they, and what do...
  13. M

    where to buy hepvo valves

    Am after the above. Anyone know a good place to buy them from? They're expensive in bes and even more expensive with angled adaptor to connect onto bath.
  14. M

    gas engineer near harrow

    Hey chaps, got a call from someone in harrow. Pressure gauge in red, prv discharging and heating not turning off with stat. Not my jurisdiction. It's a vailliant combi
  15. M

    Anyone want a nights work in Harrow?

    I say night as it is from around 10pm to 6am tomorrow. It is hanging a boiler, piping last meter of pipework on a system boiler, wiring and filling up system. The wiring is for 3 zones. Unvented hot water and 2 heating. I would love to do it on my own but cannot as have never wired up a system...
  16. M

    LST radiator covers

    Does anyone know a good place to buy them? Cheers
  17. M

    room stats

    Hi chaps, I got a danfoss standaRd room stat. Am not getting any audibel click when turning it up or down, when heating is on, am getting 230v at terminal 4 and . Even when I turn it up and down. Is this correct? As it is not calling for heat at wiring centre. So not getting any heating. Wires...
  18. M

    what kind of flush is this?

    I have not seen one of these flush valves before so need to know if I can use any washer for the flush valve as it is constantly flowing into the toilet. And what is the make of this flush
  19. M

    just studying s plan wiring diagrams...

    With different programmers. I see in the honeywell wiring guide, using the honeywell wiring centre it has in the back a list of programmers to connect into this circut, and where to connect the terminals into the wiring centre. With the horstmann 2 channel programmer, it says put the hw off...
  20. M

    veissmann 100 W system, combi boiler

    Has anyone any experience with these? I was going to fit a 40kw heat only boiler but, have now kind of gone off the idea due to it being on view and vessel and pump being on show. And, although my calcs ( measuring being ft3 x 5 x 3142) say I need 40kw, but another quote they had specifying a...