Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. M

    vokera 29 he

    Hi, A little help needed, been to above mentioned boiler today, running ok for small periods at a time. When I pull open the combustion cover the boiler works fine. So air in or out issue. I've checked venturi, cleaned heat exchanger and checked flue. Not sure its the air pressure switch as I...
  2. M

    warm air heating

    Hi, Father in law just moved into new house. His heating bill has been estimated by previous occupant(the owner). Based on his gas consumption. THe landlord has had safety check carried out and passed 2 fires, the warm air and hot water. I told him I'd gas rate them, all is ok except the warm...
  3. M

    gas rate, bigger meter?

    HI, Had to pull the school book out. on this one. Have a keston 55kw system boiler, 300 litre unvented tank, approx 150 m2 under floor heating and 14 medium sized radiator's as specified by architect. On top of that a range cooker and a combi boiler to be fitted at a later date in a granny...
  4. M

    glowworm economy plus 30f

    Hi all, A little help needed. Was called today by customer, saying boiler was making funny noises. It turns out the boiler cut's in and out every ten seconds or so, hence the noise. My first thought was thermostat, when the boiler is at full heat and then turned down the flame goes out but...
  5. M

    baxi installer?....... maybe not

    So, fitted approx 4 new neta tec's this year. As I liked the duo tec I thought I'd carry on the tradition and try them, I've read posts and imputed my take on them... overall, I like them. But now I've just had a call from second gas valve failure,( which was fitted approx 3 months ago) With...
  6. M

    baxi 105 he

    HI all. Recently posted problem with this same combi boiler last week. After much appreciated help. I'm still no further forward. I have hot water tap running, boiler runs as it should but temperature lights rise to 80 then cuts in and out. Same happens on heating. I have renewed both dhw...
  7. M

    baxi 105 he

    Hi all, Hopefully a pointer in the right direction. ABove combi boiler, hot water running at tap, boiler fires up in normal way but no matter what temp its at it heats up to 80 degrees then cut's in and out. I had initialy thought hot water stat. But the same happens on heating. No flashing...
  8. M

    condensate/relief discharge

    Hi,I am aware pressure relief pipe discharge pipe must be seen to be discharging as a warning etc. Has anyone come up with a suitable method of discharging via condensate using a tundish and a method of sealing the condensate pipe so possible fumes don't enter property [maybe incorporating a...
  9. M

    ideal logic

    Haven't been a lover of ideal boilers of old, about to fit an ideal logic, good or bad boiler?
  10. M

    best rf prog/stat

    Hi all, I have installed my fair share of radio frequency prog/stat's but haven't really used a lot of different kinds. Usually its the a budget to win job, I always feel yes it does the job but always has features missing, such as advance or you have complicated procedure in keeping heating off...
  11. M

    gas safe inspection

    Hi Has anyone had an inspection recently? Mine is a week tomorrow. Letter said I had to arrange 3 sites for inspector to visit, last time it was one with corgi that consisted of commission and safety inspection of a boiler I installed. I feel 3 sites is tricky as sometimes my gas work is few...
  12. M

    vokera compact 28

    Advise please, Problem with Vokera compact 28 dhw, hot water unstable. Hot and cold but mostly just lukewarm. I have replaced secondary thermister on hot water side. Tested flow switch, checked venturi, fan and pressure switch. Have also checked min and max modulating pressure along with...
  13. M

    boiler problem

    Hi, Some help needed, Glow worm compact 100 fanned flue system boiler is working, but cuts out before the room temperature has been reached. Initially i thought room stat but as the boiler cuts out, it makes a winding down noise that, although not loud, sound like an aeroplane falling from the...
  14. M

    leak sealer

    hi guys, just looked at a job, customer complaining of system pressure dropping about a bar overnight. he said its always happened but it was over a few months. boiler is 3 years old viessman combi. i said i would get under floor and check for leaks but he wants me to try leak sealer,pretty sure...
Back