Search results | Page 6
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. W

    Record 102 Pipe Cutter

    Record 102 3 wheel pipe cutter. Can be used in tight spaces as you can rotate backwards and foirwards without having to make a complete revolution. Will cut up to 2" steel or copper pipe. £40 including postage.
  2. W

    Hoval TKDR35 Boiler

    I have a new customer at a hotel with a Hoval TKDR35 (oil fired) to service which is about 35 years old. It's a bit of a leviathan. Looks like I'm going to have to climb inside it to clean it out. Need plenty of overalls!! The burner is just a standard two stage NuWay which is...
  3. W

    Huge DIY bodge up

    Got called out yesterday to a system overflowing. It was one of those DIY efforts - there were 6 header tanks / cisterns in 3 loftspaces. The main DHW header consisted of 2 20-gallon ones linked together (with one of them stagnant). There was an oil boiler with indirect cylinder at one end of...
  4. W

    Belfast Sink outlet with 4" flange

    Hi. looking for a sink waste with a 4" flange to fit a low type brown saltglazed sink. Standard Belfast Sink waste is too small and won't grip. Anyone know where I can get one? Thanks
  5. W

    Firebird Enviromax boilers. Any experience?

    Hi. I need a new oil boiler for the boilerhouse in a local inn. They currently have an ancient Powell Duffryn OP3 which must be at least 40 years old and on borrowed time. I am looking at the Firebird Enviromax 58kw Boilerhouse boiler which should do the job. Anyone any experience of these...
  6. W

    Looking for miniature Torbeck valves

    I'm looking for miniature side entry plastic Torbeck valves for replacements for animal drinkers. I can only find the Fordham ones around here now.
  7. W

    Biral BZ50-1 pump technical info wanted

    Hi does anyone have any instructions and technical specs for a Biral BZ50-1 circulating pump?
  8. W

    Training Centre in York Closure?

    I was due to start a new course at a training company in York called MPK Associates, however since December, the company now appears to have ceased trading and as such I am quite seriously out of pocket. No statements have been made or notices posted. If anyone knows anything about this, I...
  9. W

    Combined F&E pipe problems

    I have yet again come across a problem with a central heating circuit in my local area. Some time ago, probably in the 70s and 80s, a local tradesman decided that he only needed one pipe from the F&E cistern, and this would tee into the pipework immediately above the coil on the hot water...
  10. W

    Underfloor Heating Project

    Family friends are doing a barn conversion and are looking at underfloor heating. Not being something I have really been involved with myself, they are wanting to know what routine maintenance is required and what if any parts need replacing as time goes on, what are the usual problems /...
  11. W

    Central Heating and Hot Water Control problem

    I have the following scenario - The customer has a newish oil boiler. Instead of s-plan or y-plan, the DHW and the CH are on independent circuits, each with its own pump. The only means of control currently is a timeclock. The boiler kicks in should either the DHW timeclock or CH timeclock...
  12. W

    Emergency shower kit

    As new emergency shower kit - header tank with pull-down drench handle. Was in a swimming pool plant room, selling on behalf of customer, £80. Used in chemical stores, pool plant rooms, agrichemical dealers etc. Price includes postage
  13. W

    Tripod pipe stand and vice

    Tripod pipe stand and vice, good condition, surplus to requirements, £100, near York / Teesside.
  14. W

    Bahco Ergo Pipe Bender - anyone use it?

    Been looking at this pipe bender. Conventional pipe benders have always struck me as being fiddly and poorly designed, but I'm not so sure about parting with £75 for one that only does 15mm.
  15. W

    Gate Valve 100mm

    100mm (4") Hattersley PN6 gate valve brand new and sealed, cost about £500, accept £200. Can arrange carriage if you need. Welcome to Hattersley | Product Details for Ductile Iron & Cast Iron Gate Valves | Figure No: M549PN6
  16. W

    Unusual float valve in cistern

    This float valve is in the cistern at the hotel I mentioned on my previous post. Not come across one of these before. I presume unfastening the bolts on the flange give you access to the washer and piston. Anyone worked on one before? I am told the work dated from the 1950s or 1960s. The...
  17. W

    Header Tank Relining

    I have a customer who has a steel header tank which is starting to go in the corners. However it is built into the roof and there is no way getting it in or out without taking part of the roof off and hiring a crane. I have heard that there are companies who specialise in lining such tanks in...
Back