Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. Deleted member 32524

    powerflush machine

    Hello, Thanks for looking. I want a powerflush machine. Looking for one with a magnet in it that I can take out and clean without stopping the flush. also one that comes with fittings to put on at pump etc. Or other ideas?? only ever hired one and it was missing everything had to do them...
  2. Deleted member 32524

    Baxi Bermuda rg3

    Hello all. Looking for some advice thanks. Above gas fire has a cracked burner with a hole that looks like it has been blown through. Checked burner pressure and it is a little under so not too much pressure. Maybe worn injectors? How do you check for worn injectors? is there a tool for...
  3. Deleted member 32524

    Question for Alpha man on warranty.

    Been looking at an alpha for a customer needing a combi somewhere about 25-28kw. been pointed at 26 c intec priced at £856 inc flue. Also one says 8yr warranty then the other says no 5 yr. also what is the deal with the 28x intec. less warranty? cheers in advance.
  4. Deleted member 32524

    WB 28I rsf low inlet pressure.

    Hello folks. P1 standing pressure 23mb drops to 15 when demand comes on (dhw) Tested meter gov standing 24mb drops to 20mb but maintains that. Gas line looks to not be too long a run but does drop to 15mm quite a bit from boiler. I am thinking possibly blocked filter on GV or pipe. Can filter...
  5. Deleted member 32524

    Core Drilll Wanted 240 or 110v,

    Hello, I am looking for a core drill. In the Glasgow area. Cheers, Duncan.
  6. Deleted member 32524

    worcester bosh 28i no ignition

    Hi there, looking for some help. working on a bosh 28i junior greenstar. not igniting. got a spark but no ignition. gas valve, maybe? got current going to it but does not open on p1 when trying to ignite. maybe air pressure switch? Fan, pump running. Thanks, Duncan
  7. Deleted member 32524

    Vokera Linea Lock out.

    Hello, I have been called to a job where customer is complaining of the dhw going hot and cold. Water pressure drops and boiler going to lock out with code 02 coming up. Recently changed primary thermistor. Also recharged expansion vessel. Just wanted opinions on what it may be? Pump...
  8. Deleted member 32524

    Vokera Linea Lock out.

    Hello, I have been called to a job where customer is complaining of the dhw going hot and cold. Water pressure drops and boiler going to lock out with code 02 coming up. Recently changed primary thermistor. Also recharged expansion vessel. Just wanted opinions on what it may be? Pump...
  9. Deleted member 32524

    How to run boiler when doing a power flush

    I have done a power flush and the mis said to run boiler at around 50degrees. However, when i turned it on it banged and rattled and then shut down. Is this due to flow or what? Any ideas would help.
  10. Deleted member 32524

    Power flushing

    Hi Guys, My name is Duncan. I am a heating engineer from Glasgow. I have recently gone out on my own and have been asked by a customer to power flush their system. It is a Vokera Minute floorstanding combi boiler with old radiators that have in-line valves. Never done a powerflush and would...