Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. stings27

    Logic ES35 L2 problem

    Hi all. Have a problem with ideal combi. Working perfectly ok on heating then stopped with the L2 code. Firstly tried resetting,checked condense and flue, all ok. Gas valve is opening ok but with no ignition. Embarrassingly I’m not too familiar using a multimeter (even tho I have one !) so...
  2. stings27

    Baxi solo 2 70 pf problem

    Evening all. Have encountered a problem with neighbours boiler and wondering if one of you out there could help me. When the programmer is turned on , everything seems in order. ‘Boiler on’ lights up, ‘fan on’ lights up, ‘pilot on’ lights up then burner on. After around 5 minutes, the boiler...
  3. stings27

    Viessmann rf stat problem

    Hi all. Recently moved house and have a viesssmann vitotrol 100 UTD-RF stat. I have looked thro the operating instructions and to be honest, it might as well have been written in Chinese. Can anyone tell me if you can completely reset it so as I can put my own program in it ? (P3) When you...
  4. stings27

    Milwaukee transfer pump

    Hi all. Was looking at the Milwaukee transfer pump and wondering if it was fit for purpose ? I’m doing new build and use a drill pump to pressure test and thought this piece of kit might make life a bit easier ? Any thoughts please? Thank you.
  5. stings27

    Hot water problems Baxi duo -tec

    Hi all. Got a call from my brother in law this morning regarding a problem with his Duo-tec. When he opens the HW tap on his sink unit , the boiler will not fire but he reckons ( I have not visited due to the current situation) when he opens the taps upstairs in bathroom it does ??? Says...
  6. stings27

    Baxi VP ignition problem

    Hi all. Went to a customers house last week because they couldn’t light their gas fire. Initially I thought it was the spark generator but on closer inspection the problem looks more to do with the control assembly. If I press in the control knob gently but not fully ,it will spark& sometimes...
  7. stings27

    Baxi VP gas fire problem.

    Hi all. Had a customer ring last night regarding a problem with their baxi VP gas fire. Works fine on the 2nd setting but as soon as it’s turned up to 3 , stays lit for around 15 minutes then turns itself off. It can then be re-lit but turns itself off again. Never heard of this before wonder...
  8. stings27

    Problem with Vokera Mynute 20e

    Hi all. :smile5: Got a phone call from a friend last night complaining that his boiler was making strange noises and would not turn off. The boiler is only serving the rads as his HW is run off an Aga. On arrival I first turned down the room stat which did nothing, then turned off on...
  9. stings27

    UDHW Discharge Pipes

    Hi all. Not posted for a while but have a question re: Discharge pipe lengths. I am in ownership of my UDHW cert. but haven't worked on one for yonks....till now :thinking: Was going to run it in 22 but with the fittings, exceeds the permissable 9m..just :mad2: Do I now have to run the entire...
  10. stings27

    Pressure loss

    I'm sure this has been covered a thousand times but here go's! I had a call off a relative about 6 Months ago with a pressure loss problem on a Duo-Tec. after having a good look round the bungalow I found a small weep on a fitting behind a fridge, repaired and re-filled the boiler and everything...
  11. stings27

    Glow Worm 30cxi- No Display

    Hi all. Posted this thread on the public forum but it got closed due to me not having 'Yellow Badge' Anyway, problem solved... it was the PCB (£187.43 + ) :whatchutalkingabout Googled problem and found this on you tube...... http://youtu.be/hkRNinKJUbs E-mailed link to customer and she told me...
  12. stings27

    Glow Worm 30cxi- No Display

    Hi all Sorry for this being vague, but on my way home from work got a call from a friend who said they had had a power cut and the heating/hot water had gone off. I thought it would just be a case of resetting but my friend said she had gone to the boiler after the electric had come back on...
  13. stings27

    Gas meter union fitting.

    Hi all. Recently started on new build which I have done very little of but enjoying none the less (except lack of scrap!!!!) I will soon be air testing the gas carcasses and will require one of those black male threaded fittings that screws onto the meter union that allows you to test out. I,m...
  14. stings27

    Baxi Combi's and loss of pressure

    Is it just my bad luck or has anyone else had these problems ? Started with my old 105, having to jump up in loft to top up periodically. Fitted a Duo-tec for my Uncle 3 years ago ...having the same problem, now my Duo-tec at home giving me grief!! Is it a common problem with Baxi?
  15. stings27

    105HE pressure swtch problem.

    Went to a mates house yesterday who had no heat/water. Boiler goes thro' sequence, fan starts then nothing. Fan icon on display flashes. Followed fault finding say's to replace PS which I have. Still nothing. :angry_smile: But on removing the - tube from the flue assembly she fires. Put the tube...
  16. stings27

    Baxi 105HE

    Have a problem with a Baxi 105HE. Intermittant firing on HTG/HW Fan/flue neon flashing- checked both , seem ok. Thanks