Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. jaydebruyne

    Finding a blockage in heating pipework

    I did a powerflush a few weeks back and when I was dumping the water the flow dropped immediately. So I rang tech support (Anton) for my pump and he said it's because there's a blockage in the pipework - I tested the pump itself which was fine. It's a flat with ground and first floor. All rads...
  2. jaydebruyne

    Unvented cylinder annual service

    what exactly is done in an annual service for an invented cylinder? Other than checking no leaks, immersion elements are ok etc I have my G3 ticket. But don't be fooled, they don't teach you much on the course!!!
  3. jaydebruyne

    Making good to wall behind rads when replacing rad

    up to now I've left the wall as is when I replace a rad. What say you lot?
  4. jaydebruyne

    Chrome pipe bending and filing

    whats the best and quickest method of filing off the chrome plating on chrome 15mm copper? And is chrome pipe bendable? Any method I need to adopt to bend it? Doing a job next week fitting 10 new rads and the woman wants all rads to have chrome pipework coming up from floor.
  5. jaydebruyne

    Cast iron stack (shared waste system)

    Gonna be doing a job soon, the guy wants a 2nd toilet fitted to be connected to the existing toilet before it exits to the stack directly on other side of the wall. New toilet will be in bathroom to left of cloakroom and pass through a utility room before it reaches toilet in cloak room...
  6. jaydebruyne

    Pipework puzzle

    At a job to repipe a part 1 pipe system which has been teed from I think from pipework under boiler under floor to feed a flow/return section of the house. My understanding of a 1-pipe system is that the pipework flowed in series.. from the first rad to the last and then returned to the...
  7. jaydebruyne

    1 pipe system

    Taken on a job - woman's house is part flow/return 2 pipe and part 1 pipe system.. I'm ripping out the remaining 1 pipe and joining into the existing flow/return. Other than new valves if they're still the ones for 1 pipe systems, it no different to piping up a normal flow/return system is it...
  8. jaydebruyne

    Question on gas pressure drop across pipework

    I know it's 1mb drop max from meter to appliance. a) is this with just that one appliance demanding gas?
  9. jaydebruyne

    Vaillant Case Insulation

    Serviced a Vaillant Ecotec Plus combi the other day and all the case insulation is crumbling. Can this be bought to replace as looked for it on partsarena but couldn't see anything? Cheers
  10. jaydebruyne

    Can anyone ID this waste pump

    It's in a bathroom equipped for somebody with a disability - I've seen 2 this week funny enough, never before that.
  11. jaydebruyne

    Chasing pipes in concrete floor

    Can anyone recommend a decent pipe detector to detect pipework in concrete floors - I need to chase a pipe this afternoon and don't fancy chasing through other pipes!! Or if anyone can recommend another way??
  12. jaydebruyne

    Vented heating system

    Have come to flush a large house, vented heating, invented hot water. Go to the header tank and there's no vent pipe :/ just the feed, overflow and cold in.. Huh?!?!?
  13. jaydebruyne

    Low gas pressure

    Just finished commissioning the Vaillant boiler. Pressure slightly low at 2.76 m3/h. 30kW. Old boiler was a 24kW. Tested the hob and all burners go out on simmer. Owners reckon this is a new thing. Only hob and boiler on gas. Pipework from meter is 22mm, goes in house and under floor in 22mm...
  14. jaydebruyne

    Non Registration of Boiler Install

    Went to see a job today where a boiler had been disconnected because of the flue.. see the pic, was shocked when I saw it. Anyway, turns out an inspector from Gas Safe Register was the one who attended and ID'd it. But also the installer didn't register the boiler for building regs compliance...
  15. jaydebruyne

    Worcester Greenstar 18ri

    Got called to a boiler leaking but only when it rains. Checked condensate pump, works fine and no blockages. Checked no blockages in condensafe neutraliser and all good. Opened up the cover and water on the bottom. Dried it out and ran boiler on max for a while but no leaks. Checked sump of...
  16. jaydebruyne

    Ideal Logic Service Notice

    How do I get rid of the service alert on the display on a logic +?
  17. jaydebruyne

    Ecotec Plus 824 combi

    How do the side panels come off? Sorry for stupid question! Just don't look like they do but I thought they did
  18. jaydebruyne

    Flue

    Is this kind of thing allowed? Half in and out the wall?
  19. jaydebruyne

    3 & 2 port on same vented system

    Went to look at a job tonight.. when looking at the system it had a 3 port underneath the boiler and a 2 port just before the vented cylinder.. wtf?! Why would that be?
  20. jaydebruyne

    Fan Pressure Test

    So I did my first full Worcester Greenstar service today.. cleaned out the burner and didn't bother testing the fan pressure to see if it needed it or not. Mainly being that the mis say to do it with a digital gauge and I don't have one. Can it not be done with a normal u-gauge?