Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. jaydebruyne

    Hep2o in Heating Installs

    Worcester say a minimum of 600mm before joining into plastic, Baxi say 300mm, other mis have no requirement. Why exactly is it that some manufacturers have specific lengths before joining into plastic? I've just read the data sheet for hep pipe and although it may shorten the 50 year life...
  2. jaydebruyne

    Vaillant EcoTec Plus 428

    It's not going above 42 degrees. Burners on. Have checked thermostat and it's working fine. It ramps up every now and temp goes to 65 degrees for about 10 seconds and then ramps straight back down and temp goes back to 42...???? Didn't go as far as to check the thermistor as it was bloody late...
  3. jaydebruyne

    Vaillant ecotec Plus 428

    It's not going above 42 degrees. Burners on. Have checked thermostat and it's working fine. It ramps up every now and temp goes to 50 odd and then ramps straight back down and temp goes back to 42...????
  4. jaydebruyne

    Grundfos Heating Pump

    4 floor terraced house with 15 rads - only a 15-60. That's crazy, right? They go through pumps every 2 years so I've recommended a bigger pump. What's the best way to size up pumps in relation to number of rads / floors / size of house.
  5. jaydebruyne

    Worcester Greenstar 24i Jnr

    Never come across this before.. Boiler in demand for heating, sounds like running water from the bottom of the flue where it meets the condense trap, also a gurgling sound from the terminal (went to check for blockages). Condense run blocked? Boiler keeps locking out. Also, fan sounds like...
  6. jaydebruyne

    Worcester DHW Flow Turbine

    This is just a flow sensor, right? It detects flow and activates boiler startup & diverter valve...
  7. jaydebruyne

    Worcester 28SI II

    Went to a. Real down this evening. Reset the boiler, lit up, started kettling. Checked the pump and found it is weak so gonna replace that tomorrow. Obv it then shut down and went into lock out. Reset it, same thing happened. But this time the flames were kinda pulsating. Checked gas valve...
  8. jaydebruyne

    Pipe ID

    This ain't 4 inch I'm sure - what could this be?? I need to replace that white socket which a toilet pan connector goes into. This is a commercial install.
  9. jaydebruyne

    Worst rad valves

    Fitted these along with a column rad - the most hideous valves I've ever seen!!!
  10. jaydebruyne

    Filling Station

    Took me a while to figure out this was actually the filling loop to the system today - constantly open inlet with a 1.5 bar pressure reducing valve and expansion vessel - never seen it done like this before :/
  11. jaydebruyne

    Damp & Mouldy Cylinder/Cistern cupboard

    Went to a private job today - no hot water. Turned up and was shown to the cupboard inside the bathroom where the cylinder and cistern reside - WOW! The only extractor fan in the room is not working. No vents on the cupboard Fused spurs damaged from condensation and both rusted and blown Both...
  12. jaydebruyne

    Couple of questions

    1. Condense pumps (Jet branded) - this one has earth neutral live and 2 black wires for hi limit cut out. I just connected the LNE and omitted the black wires. Would this cause the pump to not work correctly? 2. Surely I can run the condense from the pump in any direction? I've had to run it...
  13. jaydebruyne

    Rads on plasterboard walls

    How's best to fit them on plasterboard walls? No studs found. Underneath a window. Double panel. 1600 x 300
  14. jaydebruyne

    New Towel Rad

    A friend of the Mrs just asked me if I can fit a new towel rad.. I said sure. They just had their bathroom refurbed and the rad is the last thing. Out of curiosity I asked her to send me pic of the pipework for the existing rad.. I just shook my head!!!
  15. jaydebruyne

    Plastic Stack Repair

    I've not done too much 4" work - as far as I can tell the boss goes into the socket above, then a short piece of pipe with a socket fits around the bottom which goes into another socket in the ground. I need to replace the boss and pipework underneath it going into the socket in the ground...
  16. jaydebruyne

    2 inch Copper Waste Pipe

    Last year the 2 inch copper pipe had a split in it so I cut it off and replaced it with plastic and joined it back to the 2 inch copper with a universal compression fitting. The last part of the pipe has now split so my options are: Cut the elbow off and extend the plastic to there - but I'll...
  17. jaydebruyne

    Fire Tube

    I have a job in my diary tomorrow to fit a new 8mm fire tube.. Errr... ??? It's for a gas fire apparently... So.. Where are these situated and what exactly do they do? Sorry, I must sound dumb! I googled it but it just comes up with fire tube boilers...
  18. jaydebruyne

    Gas Safe Register

    I want to get my own personal gas safe registration rather than being registered through my firm. a) I'm already anxious about the meeting with the engineer and I haven't even booked yet b) what kind of things do they ask? Is it a difficult grilling from them? I don't know what to expect which...
  19. jaydebruyne

    New heating controls and wiring

    I just need confirmation I'm doing this right as per my drawing.. Not sure if this is clear enough.. but... I've replaced an old mechanical timer and room stat and had to rewire as custard wanted them relocated. I was trying to do this without a wiring centre and it kept blowing the fuse...
  20. jaydebruyne

    Vertical rads

    I've never fitted a vertical rad yet but will be doing so on Saturday. . I've done a little research and know it's important to pipe up the flow on the correct side of the rad so it flows through the entire rad and not just the outside. My question is this: Say the flow is on the left, can...